Zero Export Device EFR4001IP
Ready to ship today,
Delivery time appr. 1-3 workdays
Relays for energy flow EFR4001IP monitor the current flow between public power grid and generating plant / consumer. Operation is made comfortably via integrated webserver or directly at the device. Measured values are displayed neatly arranged at device on monitor. When the own power plant generates more power than is actually consumed, rather than selling the excess energy to the grid provider, self-consumption is often more economical. This is especially reasonable when the difference is high between the price you pay to the grid provider and the price the provider pays for fed in energy.
Many areas suitable for photovoltaics could not be used so far, since only a limited amount of power can be fed in at the grid connection point. In Germany new standards allow exceeding this value by up to 2/3 (66.6%) installed capacity. The prerequisite for this is that the overbuilt power is consumed and not fed into the grid. In order to still ensure the stability of the system, this must be monitored. The same applies to zero export, when no energy at all may be fed into the grid. In this case, the device can be used as an energy flow direction sensor (EnFluRi). The EFR4001IP has been optimized for these functions.
Zero-Export-Device or limiter:
- Switching off the power generation system or parts of it if the permissible feed-in power is exceeded with relay K3
- Switching on consumers or reducing generators before it comes to that by means of regulating with an analogue output or switching loads with relays K1 and K2
- Energy flow direction sensor (EnFluRi sensor) and feed-in limitation < 0.1s
Suitable current transformers:
- Usual current transformers up to 2,400 A, secondary 1 A or 5 A (for Pav,e min. class 1), e.g. ZIEHL type AS or WS
- Compact CTM7 CTM7, 64/1 A, Kl. 1, 0,5 VA
- Split core KBR18S KBR18S, 60/1 A, Kl. 3, 0,4 VA (not for Pav,e)
Accessory:
NEW: Zero Export Device Typ EFR4002IP
- You want to use 3 inputs for customary current transformers with secondary 1 or 5 A?
- You want to use medium-voltage applications and connect earthed medium-voltage transformers and series connected measuring devices?
- You want to comply with the German regulation "NELEV" and "EAAV"?
Then have a look at our new EFR4002IP!
Product group: | Mains Monitoring, New Products |
---|---|
Input/ Measured parameter: | Voltage, Power |
Outputs: | 2 Ausgänge, Analog outputs 0/4-20 mA, 0-10 V, Outputs/Relays, Ethernet TCP/IP |
Supply voltage: | AC/DC 24 - 270 V |
Design: | Mount in switchgear cabinet, Mount in circuit breaker box |
Approval: | UKCA, EU-Declaration of Conformity, Extras |
Applications: | Wind energy plants, Plants for Generation of own energy, Heat and power plants |