The MSF 220 V is particularly suitable for the temperature monitoring at dry transformers. 3 PTC-circuits with different nominal response temperatures (NRT) can be connected to this unit, one for controlling a fan (forced cooling) and two for alarms. Each PTC-circuit is monitored for break and short circuit. This reduces the probability of false alarms.

  • 3 PTC-circuits
  • MSF 220 VU for universal supply voltage AC/DC 24-240 V
  • intelligent control of fan (relay K0, 1 normally-open contact)
  • ALARM 1 in closed-circuit current mode (relay K1, 1 change-over contact) for pre alarm. Signals also error in any sensor and interruption of supply voltage.
  •  ALARM 2 in operation current mode (relay K2, 1 changeover contact). No signal when switching on and off the supply voltage.
  • all output relays potentially separated from each other.
  • monitoring of sensor lines
  • TEST-button (stop possible before ALARM 2)
  • Simple testing with disconnectable monitoring of break and short circuit  (for 10 minutes).
  • LEDs for ON, sensor error, Fan, ALARM 1 and ALARM 2
  • UL recognized component
  • plug-in terminals
  • housing for mounting on DIN-rail or wall-mount
  • mounting height 55 mm
  • Accessory: Installation Frame ER4 for panel mount
 

Accessories

Front Mounting Kit Type ER
Version: ER4, Housing V4, 4 TE
You found a device in that meets your requirements and you want to install it in a control panel or in the door of a control cabinet?With the installation frame of the ER series, this is possible for all ZIEHL devices in housings V4, V6 and V8 (width 70/105/140 mm).Enclosed by a high-quality frame made of anodized aluminum, all displays can be read outside the control cabinet. Switches, buttons and joystick can be operated. 
MS-Tester
Normal PTC-resistor relays can be tested by simply disconnecting the sensor. PTC-resistor relays with monitoring of sensor short-circuit and break need more sophisticated test-equipment.With help of the ZIEHL MS-Tester also these relays can be easily tested for correct function. The included cable is designed for the connection of relays type MSF 220 V(U). Also any other PTC-resistor relay can be connected to the MS-Tester.Testdisconnect the PTC-resistor relayconnect the MS-Tester (T/0, T/1 and/or T/3) to the sensor inputsswitch on the relayincrease the resistance with the potentiometer (turn slowly) until the appropriate Alarm switchesreduce the resistance until the relay switches back (or a LED signals, that it is ready to switch back)if necessary, the values of the switching points can be measured at the terminals T/0, T/1, T/2 after disconnecting the relay. Typical values are 3000 O ... 4000 O for tripping and >1500 O for switching back.test break with push-button (only at relays with monitoring of sensor/line-break)test short circuit with push-button (only at relays with monitoring of sensor/lineshort-circuit)ATTENTION: At relay MSF 220 V(U), break or short-circuit in any sensor will result in an error message = ALARM 1. The LED "sensor" lights and the LED of the appropriate alarm blinks.HINT: cold PTCs have a resistance of 20...250 O, typical 50...120 O per sensor.
Questions about PTC-Resistor Relay MSF220V/ MSF220VU
ProxaChatbaseAI.questions.logo

Zetty

Digital Assistant

ProxaChatbaseAI.questions.logo

Welcome to ZIEHL industrie-elektronik GmbH + Co KG! I am Zetty, your digital assistant. Since many of my answers are generated by artificial intelligence, please double-check important information to make sure everything is correct.

Content partly AI-generated. Before using our products, it is necessary by qualified personnel is required. No liability for incorrect information. Learn more
ProxaChatbaseAI.questions.logo