Universal-Measuring Transducer/ Isolating Amplifier Type MU100U

Discontinued model - remaining stock available: Discover our succeccor with small differences, the MU1000K

The universal measuring transducer MU100U can be connected to any supply voltage AC or DC between 24 and 240 V. Input signals and output signals are electrically isolated from each other. Signals DC 0/4-20 mA or 0-10 V can be connected to the inputs. The input signals are transduced to standard-signal 0-10 V, 0/4-20 mA at the outputs.

The measuring signal applied to one of the inputs is converted into a normalized voltage signal and changed into a frequency. The frequency signal is transferred by means of an optocoupler for electrical isolation. It is then converted again into a voltage and amplified. Signals 0/4-20 mA and 0-10 V are now available at the outputs. The electronics before and after the optocoupler are supplied from the power supply unit with potential separated voltages each.

It is often necessary to separate the potentials of signals by means of isolation amplifiers as otherwise this would lead to adulteration of measuring values because of compensating currents. Furthermore, the low-voltage side is effectively protected against damage caused by malfunctions at the primary side. Because of the variety of the current standard signals (0-20 mA, 4-20 mA, 0-10 V), it often happens that the output of a measuring transducer is not compatible with the input of the evaluation unit. MU 100 U eliminates these problems. Stockkeeping is largely facilitated by the universal supply voltage and different input and output signals in one device. These measuring transducers almost always fit.

  • Input signals DC 0 - 20 mA, 0 - 10 V
  • Output signals DC 0 - 20 mA, 0 - 10 V
  • Offset with signals 4 - 20 mA can be compensated by the user
  • Universal supply voltage AC/DC 24 - 240 V
  • electrical isolation between inputs and outputs (3-way isolator)
  • supply voltage for external measuring transducers -5/+18 V/ max. 30 mA
  • Isolation voltage 2.5 kV

Discover the difference between our MU series!

Type MU100U MU1000K MU1001K MU2000K
Measuring values 0/4…20 mA, 0–10 V 0/4…20 mA, 0–10 V, PT100 0…±60/150/300 mV DC, 0…±10/300 V DC 0…30/150/300/600 V AC/DC, 0…1/5 A AC/DC
Output signals 0/4…20 mA, 0–10 V 0/4…20 mA, 0/2–10 V 0/4…20 mA, 0/2–10 V 0/4…20 mA, 0/2–10 V
Scaling adjustment 2 potentiometers 2 buttons: programs or signal calibration 2 buttons: programs or signal calibration 2 buttons: programs or signal calibration
Display LEDs 1× Power 1× Power, 3× Setting 1× Power, 3× Setting 1× Power, 3× Setting
Test voltage between potentials 2500 V 3540 V 3540 V 3540 V
Input resolution n/a 14 bit 14 bit 14 bit
Output resolution n/a 11.6 bit: < 3.1 mV; < 6.1 µA 11.6 bit: < 3.1 mV; < 6.1 µA 11.6 bit: < 3.1 mV; < 6.1 µA
Housing type K K K K
Measuring time ~50 ms Voltage/current: < 20 ms;
Temperature: < 350 ms
< 20 ms Adjustable measurement time
Main areas of application Signal isolation Signal isolation Signal conversion, voltage measurement Voltage and current measurement
Approval: UL/CSA, EU / UKCA-Declaration of Conformity
Design: Mount in switchgear cabinet
Input/ Measured parameter: Standard signals 0/4-20 mA, 0-10 V
Outputs: Analog outputs 0/4-20 mA, 0-10 V
Product group: Measuring Transducers
Supply voltage: AC/DC 24-240 V
Skip product gallery

MU-series

Bild 1 Universal-Messumformer Typ MU1000K
Universal-Measuring-Transducer Type MU1000K

Universal-measuring-transducers MU1000K can measure signals Pt100 (RTD) and DC current (0/4-20 mA) and voltage (DC 0/2-10 V). Several measuring-ranges are pre-programmed. More can be easily scaled. Temperatures at sensors Pt 100 can be evaluated from -200 °C to + 800 °.The output-signals 0/2-10 V and 0/4-20 mA are potentially separated from inputs and supply voltage. With its universal power-supply AC/DC 24-240 V the measuring transducer can be connected to all common supply-voltages. It can be used as an isolating amplifier for 0-10 V signals.Overview of functionsCurrent input 0-20mA, scalableVoltage input 0-10V, scalableInput Pt 100, 3-wire, -200…+800 °C, scalableOutput signal 0-20mA and 0-10V or 4-20mA and 2-10VRated Supply Voltage AC/DC 24-240VInsulation between inputs, outputs and supply voltage (3-way isolator)Standard ranges adjustable, universally scalable input ranges Discover the difference between our MU series! Type MU1000K MU1001K MU2000K Measuring values 0/4…20 mA, 0–10 V, PT100 0…±60/150/300 mV DC, 0…±10/300 V DC 0…30/150/300/600 V AC/DC, 0…1/5 A AC/DC Output signals 0/4…20 mA, 0/2–10 V 0/4…20 mA, 0/2–10 V 0/4…20 mA, 0/2–10 V Scaling adjustment 2 buttons: programs or signal calibration 2 buttons: programs or signal calibration 2 buttons: programs or signal calibration Display LEDs 1× Power, 3× Setting 1× Power, 3× Setting 1× Power, 3× Setting Test voltage between potentials 3540 V 3540 V 3540 V Input resolution 14 bit 14 bit 14 bit Output resolution 11.6 bit: < 3.1 mV; < 6.1 µA 11.6 bit: < 3.1 mV; < 6.1 µA 11.6 bit: < 3.1 mV; < 6.1 µA Housing type K K K Measuring time Voltage/current: < 20 ms;Temperature: < 350 ms < 20 ms Adjustable measurement time Main areas of application Signal isolation Signal conversion, voltage measurement Voltage and current measurement

Bild 1 Universal-Messumformer Typ MU1001K
Measuring-Transducer Type MU1001K

Universal Measuring-Transducers MU1001K can measure DC-signals up to 300 V. Inputs 60/150/300 mV measure direct current. Pre-set measuring-ranges can be selected by the user. More measuring-ranges (zero and full scale) can be easily scaled. The output-signals DC 0/2-10 V and 0/4-20 mA are insulated from measuring-input and supply-voltage.With its universal power-supply AC/DC 24-240 V the measuring-transducer can be connected to all common supply-voltages. It can be used as an isolating amplifier for 0-10 V signals.Overview of functionsOutput signal 0-20mA and 0-10V or 4-20mA and 2-10VRated Supply Voltage AC/DC 24-240VInsulation between inputs, outputs and supply voltage (3-way isolator)Standard ranges adjustable, universally scalable input rangesInputsDC -300 … 300 mV (preset values: 0…60 / 0…150 / 0…300 / -60…60 / -150…150 / -300…300 mV)DC -10 … 10 V (preset values: 0…10 / 2…10 / -10…10 V)DC 0 … 300 V (preset values: 0…20 / 0…50 / 0…100 / 0…200 / 0…300 V)Zeros and Full Scales for more measuring-ranges can be freely selected by the user.Changes from T236006.1 to T236017: Version with spring terminals RoHS/REACH compliantFurther information can be found in our customer information: "New terminals for K-type devices" Discover the difference between our MU series! Type MU1000K MU1001K MU2000K Measuring values 0/4…20 mA, 0–10 V, PT100 0…±60/150/300 mV DC, 0…±10/300 V DC 0…30/150/300/600 V AC/DC, 0…1/5 A AC/DC Output signals 0/4…20 mA, 0/2–10 V 0/4…20 mA, 0/2–10 V 0/4…20 mA, 0/2–10 V Scaling adjustment 2 buttons: programs or signal calibration 2 buttons: programs or signal calibration 2 buttons: programs or signal calibration Display LEDs 1× Power, 3× Setting 1× Power, 3× Setting 1× Power, 3× Setting Test voltage between potentials 3540 V 3540 V 3540 V Input resolution 14 bit 14 bit 14 bit Output resolution 11.6 bit: < 3.1 mV; < 6.1 µA 11.6 bit: < 3.1 mV; < 6.1 µA 11.6 bit: < 3.1 mV; < 6.1 µA Housing type K K K Measuring time Voltage/current: < 20 ms;Temperature: < 350 ms < 20 ms Adjustable measurement time Main areas of application Signal isolation Signal conversion, voltage measurement Voltage and current measurement

Bild 1 Universal-Messumformer Typ MU2000K
Universal Measuring Transducer Type MU2000K

Measuring transducers MU2000K can measure DC- an AC-voltages up to 600 V and DC- and AC-currents 0-1/5 A.Preset measuring ranges can be selected. More measuring ranges (zero and full-scale) can be easily scaled. The output signals DC 0/2-10 V and 0/4-20 mA are insulated from measuring input and supply voltage. With its universal supply voltage AC/DC 24-240 V the measuring transducer can be connected to all common supply voltages.The MU2000K e.g. is suitable for measuring DC voltages and charging currents at batteries or for measuring AC voltages and currents in plants for own generation of energy.Changes from T236053 to T236056: Version with spring terminals RoHS/REACH compliantFurther information can be found in our customer information: "New terminals for K-type devices"Overview of functionsOutput signal 0-20mA and 0-10V or 4-20mA and 2-10VRated Supply Voltage AC/DC 24-240VInsulation between inputs, outputs and supply voltage (3-way isolator)InputsAC/DC 0 … 600 V (preset values: 0…30 V / 80…120 V / 0…150 V / 0…300 V / 0…600 V)AC/DC 0 … 5 A (preset values: 0…1 A / 0…5 A)In measuring ranges for AC also DC-signals can be measured. Negative signals will be measured as positive signals.Zeros and Full Scales for more measuring-ranges can be freely selected by the user. Discover the difference between our MU series! Type MU1000K MU1001K MU2000K Measuring values 0/4…20 mA, 0–10 V, PT100 0…±60/150/300 mV DC, 0…±10/300 V DC 0…30/150/300/600 V AC/DC, 0…1/5 A AC/DC Output signals 0/4…20 mA, 0/2–10 V 0/4…20 mA, 0/2–10 V 0/4…20 mA, 0/2–10 V Scaling adjustment 2 buttons: programs or signal calibration 2 buttons: programs or signal calibration 2 buttons: programs or signal calibration Display LEDs 1× Power, 3× Setting 1× Power, 3× Setting 1× Power, 3× Setting Test voltage between potentials 3540 V 3540 V 3540 V Input resolution 14 bit 14 bit 14 bit Output resolution 11.6 bit: < 3.1 mV; < 6.1 µA 11.6 bit: < 3.1 mV; < 6.1 µA 11.6 bit: < 3.1 mV; < 6.1 µA Housing type K K K Measuring time Voltage/current: < 20 ms;Temperature: < 350 ms < 20 ms Adjustable measurement time Main areas of application Signal isolation Signal conversion, voltage measurement Voltage and current measurement

Questions about Universal-Measuring Transducer/ Isolating Amplifier Type MU100U
ProxaChatbaseAI.questions.logo

Zetty

Digital Assistant

ProxaChatbaseAI.questions.logo

Welcome to ZIEHL industrie-elektronik GmbH + Co KG! I am Zetty, your digital assistant. Since many of my answers are generated by artificial intelligence, please double-check important information to make sure everything is correct.

Content partly AI-generated. Before using our products, it is necessary by qualified personnel is required. No liability for incorrect information. Learn more
ProxaChatbaseAI.questions.logo