Universal Measuring Transducer Type MU2000K
Ready to ship today,
Delivery time appr. 1-3 workdays
Do you have a question?
Measuring transducers MU2000K can measure DC- an AC-voltages up to 600 V and DC- and AC-currents 0-1/5 A.
Preset measuring ranges can be selected. More measuring ranges (zero and full-scale) can be easily scaled. The output signals DC 0/2-10 V and 0/4-20 mA are insulated from measuring input and supply voltage. With its universal supply voltage AC/DC 24-240 V the measuring transducer can be connected to all common supply voltages.
The MU2000K e.g. is suitable for measuring DC voltages and charging currents at batteries or for measuring AC voltages and currents in plants for own generation of energy.
Changes from T236053 to T236056: Version with spring terminals RoHS/REACH compliant
Further information can be found in our customer information: "New terminals for K-type devices"
Overview of functions
- Output signal 0-20mA and 0-10V or 4-20mA and 2-10V
- Rated Supply Voltage AC/DC 24-240V
- Insulation between inputs, outputs and supply voltage (3-way isolator)
Inputs
- AC/DC 0 … 600 V (preset values: 0…30 V / 80…120 V / 0…150 V / 0…300 V / 0…600 V)
- AC/DC 0 … 5 A (preset values: 0…1 A / 0…5 A)
- In measuring ranges for AC also DC-signals can be measured. Negative signals will be measured as positive signals.
Zeros and Full Scales for more measuring-ranges can be freely selected by the user.
Discover the difference between our MU series!
| Type | MU1000K | MU1001K | MU2000K |
|---|---|---|---|
| Measuring values | 0/4…20 mA, 0–10 V, PT100 | 0…±60/150/300 mV DC, 0…±10/300 V DC | 0…30/150/300/600 V AC/DC, 0…1/5 A AC/DC |
| Output signals | 0/4…20 mA, 0/2–10 V | 0/4…20 mA, 0/2–10 V | 0/4…20 mA, 0/2–10 V |
| Scaling adjustment | 2 buttons: programs or signal calibration | 2 buttons: programs or signal calibration | 2 buttons: programs or signal calibration |
| Display LEDs | 1× Power, 3× Setting | 1× Power, 3× Setting | 1× Power, 3× Setting |
| Test voltage between potentials | 3540 V | 3540 V | 3540 V |
| Input resolution | 14 bit | 14 bit | 14 bit |
| Output resolution | 11.6 bit: < 3.1 mV; < 6.1 µA | 11.6 bit: < 3.1 mV; < 6.1 µA | 11.6 bit: < 3.1 mV; < 6.1 µA |
| Housing type | K | K | K |
| Measuring time | Voltage/current: < 20 ms; Temperature: < 350 ms |
< 20 ms | Adjustable measurement time |
| Main areas of application | Signal isolation | Signal conversion, voltage measurement | Voltage and current measurement |
| Applications: | Wind energy plants, Plants for Generation of own energy |
|---|---|
| Approval: | UL/CSA, UKCA |
| Design: | Mount in switchgear cabinet |
| Input/ Measured parameter: | Voltage, Current measuring |
| Outputs: | Analog outputs 0/4-20 mA, 0-10 V |
| Product group: | Measuring Transducers |
| Supply voltage: | AC/DC 24-240 V |