Skip to main content Skip to search Skip to main navigation
Go to homepage

Measuring Point Change-over Switch Type MUM8

Measuring point change-over switches allow the connection of up to 16 measuring points to 1 measuring device, e.g. an analog input of a PLC.

The inputs can be selected with a BCD-Code. Manual selection can be made with a code-switch. 

In automatic mode, the inputs are polled (tact-time adjustabe) and thus be displayed in succession. When using a measuring point change-over switch, only 1 measuring input is needed to collect multiple values.
Especially with slowly changing signals like temperatures, measuring every other second is enough. Expensive inputs for Pt100 or 0-10 V/0-20 mA at PLCs can be saved.

With the MUM8, alternatively 8 measuring points with common ground or 4 measuring points with separated ground can be switched.

  • PLC-compatibel. Channelselection over 3 bit parallel (24 V), e.g. PLC or by a code switch
  • Optional switching + or -
  • 8 channels (0/4 ... 20 mA, 0 ... 10V, Pt 100) with common ground
  • 4 double-channels (= Pt 100/3-wire and thermocouples) 
  • Supply-voltage AC 230 V or DC 24 V
  • LED-display for selected channel
  • Clock time in automatic mode adjustable 0,5 ... 10 s
  • plug-in terminals
Product group: Measuring Transducers
Input/ Measured parameter: Standard signals 0/4-20 mA, 0-10 V, Pt 100
Outputs: Analog outputs 0/4-20 mA, 0-10 V
Design: Mount in switchgear cabinet
Approval: EU / UKCA-Declaration of Conformity
Extras: more than 3 sensor inputs, Temperature sensors

Technical specifications

Skip product gallery

Alternativ

Bild 1 Messstellenumschalter Typ MUM16
Measuring Point Change-over Switch Type MUM16

Measuring point change-over switches allow the connection of up to 16 measuring points to 1 measuring device, e.g. an analog input of a PLC.The inputs can be selected with a BCD-Code. Manual selection can be made with a code-switch. In automatic mode, the inputs are polled (tact-time adjustabe) and thus be displayed in succession. When using a measuring point change-over switch, only 1 measuring input is needed to collect multiple values.Especially with slowly changing signals like temperatures, measuring every other second is enough. Expensive inputs for Pt100 or 0-10 V/0-20 mA at PLCs can be saved.With the MUM16, alternatively 16 measuring points with common ground or 8 measuring points with separated ground can be switched.PLC-compatibel. Channelselection over 4 bit parallel (24 V), e.g. PLC or by a code-switchOptional switching + or -Enable-input for using multiple MUM in parallelMonitoring of up to 16 signals for one limit with only 1 limit switch16 channels (0/4 ... 20 mA, 0 ... 10V, Pt 100) with common ground8 double-channels (= Pt 100/ 3-wire and thermocouples)Simple configuration with 3 DIP-switchesSupply AC/DC 24-240 VLED-display for selected channelTact-time in automatic mode adjustable 0,5 ... 10 splug-in terminalsHousing for mounting in switchgear cabinets or fuse boxes, 140 mm wide, mounting height 55 mm

Skip product gallery

Cross Selling

Bild 1 Messstellenumschalter Typ MUM16
Measuring Point Change-over Switch Type MUM16

Measuring point change-over switches allow the connection of up to 16 measuring points to 1 measuring device, e.g. an analog input of a PLC.The inputs can be selected with a BCD-Code. Manual selection can be made with a code-switch. In automatic mode, the inputs are polled (tact-time adjustabe) and thus be displayed in succession. When using a measuring point change-over switch, only 1 measuring input is needed to collect multiple values.Especially with slowly changing signals like temperatures, measuring every other second is enough. Expensive inputs for Pt100 or 0-10 V/0-20 mA at PLCs can be saved.With the MUM16, alternatively 16 measuring points with common ground or 8 measuring points with separated ground can be switched.PLC-compatibel. Channelselection over 4 bit parallel (24 V), e.g. PLC or by a code-switchOptional switching + or -Enable-input for using multiple MUM in parallelMonitoring of up to 16 signals for one limit with only 1 limit switch16 channels (0/4 ... 20 mA, 0 ... 10V, Pt 100) with common ground8 double-channels (= Pt 100/ 3-wire and thermocouples)Simple configuration with 3 DIP-switchesSupply AC/DC 24-240 VLED-display for selected channelTact-time in automatic mode adjustable 0,5 ... 10 splug-in terminalsHousing for mounting in switchgear cabinets or fuse boxes, 140 mm wide, mounting height 55 mm

Questions about Measuring Point Change-over Switch Type MUM8