Tip
Relay for Voltage and Frequency UFR1002IP
NEW: For the German regulation "NELEV" and "EAAV"The grid decoupling relay UFR1002IP is the "big brother" of the UFR1001E and monitors voltage and frequency in three-phase and AC grids.With a color LCD display (German/English) and joystick, it is even easier to operate than the UFR1001E. Measured values and settings are clearly displayed. The device can be programmed, updates installed and the alarm memory read out via the integrated IP interface. The real-time clock (with power reserve) simplifies the traceability of the alarms. Up to 1,200 V can be monitored in conjunction with the VG1200 coupling device. The device has a two-channel, single-fault-safe design and thus meets the requirements of VDE-AR-N 4105:2018-11. The function of the connected switch is monitored. If monitoring is activated, the device does not switch on again if a switch-off error is detected.Limit values for different applications are preset. Where permitted, they can easily be changed. If the nominal voltage is changed, the device automatically adjusts the limit values. With the standby input, a remote shutdown can be implemented, e.g. with a ripple control receiver.Monitoring ofUnder/over voltage 15-520V (with ZIEHL VG1200 coupling device up to 1,200 V)Under/over frequency 45-65 HzVoltage quality (10-minute average)Vector shift 2-65°ROCOF, rate of change of frequency df/dt 0.100...5.000 Hz/sZero voltage U0 (ANSI 59v0)passive anti islanding protectionFeatures:single-fault-proof, with monitoring of connected switch (can be switched off when using the integrated switch of PV and battery convertersProgrammable restart attempts in the event of a switch-on error in the connected switchRelay K3 with programmable functions, including life contact, delayed switch-on signal for switches or error messagesResponse time adjustable 0.05 … 300,0 sSwitch-back time adjustable 0 … 6,000 sPreset according to VDE-AR-N 4105-2018-11 (Pr 1.02, Pr 1.08 + 1.09) and VDE-AR-N 4105-2011-08 (Pr 1.01)Preset according to VDE-AR-N 4110-2018-11 (Pr 1.11-1.14) and bdew guideline (Pr 1.03-1.06)automatic adjustment of the switching points when the nominal voltage is changedAlarm counter for 100 alarms (with trigger value, cause and date/time, time of restart)3 programmable digital inputsStandby counter and timer with standby on/off date/timeTest and simulation function with measurement of switch-off timesSealing option and code protection for settingsInterface ethernet TCP/IP, values available via modbus TCPSimple commissioning and programming thanks to preset basic programs and transmission via IP interfaceSupply voltage AC/DC 24-270 VHousing for DIN-rail-mount, 105 mm wide, mounting height 66 mmAccessory: Installation frame ER6 for panel mount
Zero Export Device Type EFR4002IP
Relay for Energy Flow, optimization of self-consumption of self generated energy. Zero Export Device.Relays for energy flow EFR4002IP monitor the current flow between public power grid and generating plant / consumer. Operation is made comfortably via integrated webserver or directly at the device. Measured values are displayed neatly arranged at device on monitor. When the own power plant generates more power than actually is consumed it often is more economical to consume the excess energy self. This is especially reasonable when the difference is high between the price you pay to the grid provider and the price the provider pays for fed in energy.Many areas suitable for photovoltaics could not be used so far, since only a limited amount of power can be fed in at the grid connection point. In Germany new standards VDE-AR-N 4105:2018-11 allow exceeding this value by up to 66.6% or more installed capacity. The prerequisite for this is that the overbuilt power is consumed and not fed into the grid. In order to still ensure the stability of the system, this can be monitored with EFR4002IP. The same applies to zero export, when no energy at all may be fed into the grid. In this case, the device can be used as an energy flow direction sensor (EnFluRi). The EFR4002IP has been optimized for these functions.Data exchage with PGS (Power generating system) possible.Functions:Switching of up to 3 consumers: the largest consumer, ranked 1-2-3 or combination of 3 consumers (7 levels)Switch on and off points. At which energy flow consumers are switched on and off againSwitch on and off delay of consumers, minimum on time.Control of heat pumps (SG-ready), battery chargers, invertersNEW:Can be used for medium-voltage applications Connection of earthed medium-voltage transformers and series connected measuring devicesFor the German regulation "NELEV" and "EAAV"Suitable current transformers:Current transormers scaleable up to 2.400 A, secondary 1 A or 5 A (for Pav,e min. class 1) for example ZIEHL Type AS or WSCompact CTM7, 64/1 A, Kl. 1, 0,5 VAAccessory:Front Mounting Kit ER8 for mounting in control panels or doors
Coupling Device for Voltage Type VG1200
In order to achieve higher efficiencies and to reduce line losses, inverters with a higher output voltage than the usual 3AC 400 V are often used in large on-site generation systems.So that the grid and system protection can monitor this high voltage, it must be reduced. This is usually done with voltage converters. With the VG1200 coupling device, an ohmic voltage divider is available that takes on this task. In conjunction with the VG1200 coupling device, the UFR1002IP can measure voltages of up to 1200 V. The display in the UFR1002IP is scalable. This means that the voltages at the input of the VG1200 are displayed and the limits for protection against over- and undervoltage are set accordingly. Both devices together meet the requirements of VDE-AR-N 4110 (feeding into the medium-voltage grid).Measuring of voltage up to 1200 VMeasuring tolerance = 1,2% of nominal voltage (of UFR1002IP)No voltage converters requiredDisplay of the correct voltage on the UFR1002IP (scalable)No supply voltage requiredHousing V6, 105 mm wide