New products

Bild 1 TR660IP, Temperaturrelais für Pt 100, PT1000, PTC 6 Sensoren, 7 Limits, TCP/IP
Temperature Relay Type TR660IP

Temperature Relays TR660IP monitor up to 6 sensors for up to 7 limits. Different sensors can be connected at the same time, e.g. Pt 100 (RTD) and PTC thermistors. Typical applications are monitoring of motors, generators or transformers. An other application is the use as a two or more step controller with additional monitoring of over- or undertemperature or monitoring of differences in temperatures of 2 sensors.Preset programs allow easy setting e.g. monitoring of transformers with/without monitoring of temperature of core or with/without controlling a ventilator.If the evaluation "2 out of x" is activated with several connected sensors, an alarm is only triggered when the limit value is exceeded in 2 sensors. This prevents false alarms due to a fault in one sensor. Operation can be made at the device or with a standard browser via Ethernet.6 inputs for sensors Pt 100, Pt 1000 and PTC, mixed sensors possible7 alarms / relay outputsalarm 2 of x = alarm only when limit is exceeded in min. 2 sensorsmonitoring of difference of temperaturesmonitoring of rate of change of temperaturelogging of temperatures and historypreset programs for protection of motors, transformers and moreinterface ethernet TCP/IP, values available via modbus TCPprogramming with browser via TCP/IP or with joystick at devicecoloured LED display for clear display of temperatures and states of alarmsuniversal power supply AC/DC 24-270 VAccessory: Installation frame ER8 for panel mountTR660IP RS485:  interface RS485 (modbus RTU)TR660IP analog:  4 analog outputs 2x 0/4 - 20 mA and 2x 0/2 - 10 V, isolated from sensor inputs, individually programmable. 

Bild 1 TR660IP, Temperaturrelais für Pt 100, PT1000, PTC 6 Sensoren, 7 Limits, TCP/IP
Temperature Relay Type TR660IP

Temperature Relays TR660IP monitor up to 6 sensors for up to 7 limits. Different sensors can be connected at the same time, e.g. Pt 100 (RTD) and PTC thermistors. Typical applications are monitoring of motors, generators or transformers. An other application is the use as a two or more step controller with additional monitoring of over- or undertemperature or monitoring of differences in temperatures of 2 sensors.Preset programs allow easy setting e.g. monitoring of transformers with/without monitoring of temperature of core or with/without controlling a ventilator.If the evaluation "2 out of x" is activated with several connected sensors, an alarm is only triggered when the limit value is exceeded in 2 sensors. This prevents false alarms due to a fault in one sensor. Operation can be made at the device or with a standard browser via Ethernet.6 inputs for sensors Pt 100, Pt 1000 and PTC, mixed sensors possible7 alarms / relay outputsalarm 2 of x = alarm only when limit is exceeded in min. 2 sensorsmonitoring of difference of temperaturesmonitoring of rate of change of temperaturelogging of temperatures and historypreset programs for protection of motors, transformers and moreinterface ethernet TCP/IP, values available via modbus TCPprogramming with browser via TCP/IP or with joystick at devicecoloured LED display for clear display of temperatures and states of alarmsuniversal power supply AC/DC 24-270 VAccessory: Installation frame ER8 for panel mountTR660IP RS485:  interface RS485 (modbus RTU)TR660IP analog:  4 analog outputs 2x 0/4 - 20 mA and 2x 0/2 - 10 V, isolated from sensor inputs, individually programmable. 

Bild 1 TR640IP, Temperaturrelais für Pt 100/1000, PTC 6 Sensoren, 4 Limits, TCP/IP
Temperature Relay Type TR640IP

Temperature Relays TR640IP monitor up to 6 sensors for up to 4 limits. Different sensors can be connected at the same time, e.g. Pt 100 (RTD) and PTC thermistors. Typical applications are monitoring of motors, generators or transformers. An other application is the use as a two or more step controller with additional monitoring of over- or undertemperature or monitoring of differences in temperatures of 2 sensors.Preset programs allow easy setting e.g. monitoring of transformers with/without monitoring of temperature of core or with/without controlling a ventilator.If evaluation "2 out of x" is activated with several connected sensors, an alarm is only triggered when the limit value is exceeded in 2 sensors. This prevents false alarms due to a fault in one sensor. Operation can be made at the device or with a standard browser via Ethernet.6 inputs for sensors Pt 100, Pt 1000 and PTC, mixed sensors possible4 alarms / relay outputsalarm 2 of x = alarm only when limit is exceeded in min. 2 sensorsmonitoring of difference of temperaturesmonitoring of rate of change of temperaturelogging of temperatures and historypreset programs for protection of motors, transformers and moreinterface ethernet TCP/IP, values available via modbus TCPprogramming with browser via TCP/IP or with joystick at devicecoloured LED display for clear display of temperatures and states of alarmsuniversal power supply AC/DC 24-270 VAccessory: Installation frame ER6 for panel mount ZIEHL devices neatly integrated into control panels and control cabinet doors with our installation frames type ER! More information here Discover the difference between our TR640IP, TR660IP and UR840IP! Type TR640IP TR660IP UR840IP Sensors PTC, Pt100, Pt1000 PTC, Pt100, Pt1000 Pt100, Pt1000, KTY83, KTY84, thermocouples, 0-10V, 0/4-20mA Sensor inputs 6 6 8 Digital inputs - - 4 Outputs 4x alarm relays 6x alarm relays, 2x analog (only T224370) 4x alarm relays, 1x analog Alarm types Limit value, differential, rate of change of temperature, 2 out of x Limit value, differential, rate of change of temperature, 2 out of x Sensor-specific limit values, differential, average, min/max, 2 out of x Virtual sensors - - 8 Display Display, LED Display, LED Display, LED Network / Communication Ethernet RS485 (only T224371), Ethernet RS485, Ethernet Other functions On/off delay, simulation, cyclic relay test, 2 digital inputs On/off delay, simulation, cyclic relay test, 2 digital inputs On/off delay, simulation, expansion with URB or STWA4MH Housing V6 V8 V8

Bild 1 Universal-Relais Typ UR840IP
Universal Relay Type UR840IP

Web-IO universal limit value relay with Ethernet interface, built-in web server and 8 inputs for temperature sensors or other analog signals. The UR840IP can be connected to the internet or an intranet and operated via TCP/IP from a normal PC with a suitable browser.The device can simultaneously evaluate and monitor up to 8 different input signals. Each of the 4 output relays can be assigned up to 8 limit values, one per input. If a limit value is reached, an alarm is triggered and a relay switches. Example: Alarm 1 is activated when a temperature is exceeded at sensor input 3 (e.g. Pt 100) or the signal from a pressure transmitter (e.g. 4-20 mA) at input 5 falls below a limit value. The device also has an RS485 interface (Modbus RTU) that can be used to connect current sensors type STWA4MH and the relay box type URB40.NEW: Data visualization in the web interface.Expandable by 4 additional relay outputs with the URB40! ZIEHL devices neatly integrated into control panels and control cabinet doors with our installation frames type ER! More information hereAccessory: Installation frame ER8 for panel mount ApplicationsThe UR840IP is used where one or more of the following features a required:The UR840IP is used to advantage wherever the following features are requiredmonitor up to 8 different analogue measured values and transfer them to the InternetMeasured value query and remote maintenance via intranet/internet Discover the difference between our UR series! Type UR420IP UR840IP Sensors PT100, PT1000, KTY83, KTY84, thermocouples, 0-10V, 0/4-20mA PT100, PT1000, KTY83, KTY84, thermocouples, 0-10V, 0/4-20mA Sensor inputs 4 8 Digital inputs 2 4 Outputs 2x alarm relays 4x alarm relays, 1x analog Alarm types Sensor-specific thresholds, difference, rate of change temperature, 2 out of X Sensor-specific thresholds, difference, rate of change temperature, 2 out of X Virtual sensors 4 8 Display Display, LED Display, LED Configuration Joystick, web interface Joystick, web interface Network / Communication RS485, Ethernet RS485, Ethernet Other functions On/off delay, simulation, expansion with URB or STWA4MH On/off delay, simulation, data visualization, expansion with URB or STWA4MH Housing V6 V8 Applications Measurement monitoring and control Measurement monitoring and control

Tip
Bild 1 AC-Elektronik-Stromwandler Typ STWA4MH
Electronic Current-Transducer Type STWA4MH

STWA4MH is a measuring transducer. It measures AC up to 60A and has an RS485 interface (Modbus RTU). The measured analog current value is made available as a digital signal and can be read by a PLC, an IPC or a master computer.The conductor to be measured is passed through an opening (Ø 11 mm). In case of small currents, the sensitivity of the current transducer can be increased by looping through the current-carrying conductor several times, e.g. double looping doubles the sensitivity. The measuring range of the STWA4MH is reduced by multiple looping. To measure currents of any size, the STWA4MH is simply looped into the secondary circuit of a large current transformer with a secondary output of 5A (lead the cable through STWA4MH several times).Application:The STWA4MH enables the space-saving an cost-effective measurement of the actual value of an alternating current. Compared to transducers with analog output, the bus technology significantly  reduces the effort for the hardware (inputs) and the wiring. Applications are e.g. the recording of the current consumption of electrical motors in processing machines. Here the feed can be regulated depending on the load on the motor. Another example is the monitoring of consumers, e.g. heating elements, for failure.

Bild 1 Rüttlersteuerung Typ RS2K
Vibrator Control Type RS2K

The vibrator control RS2K is a compact multiple time relay for triggering of vibrators in suction plants. In order to be able to operate suction plants at an optimum, the filters which get clogged by sawdust, chips or dust, have to be dedusted by vibration from time to time. The vibration action is by no means to be carried out the suction running or while slowing down the ventilator. If suctioning is started during vibration, the process is immediately to be interrupted. Prior to starting the vibration action, an adjustable deceleration time is running to delay the ventilator before start of vibration. This means that short stoppages can be bypassed without being obliged to carry out a vibration every time.Start of deceleration time by break contact at Y1/Z0 (e.g. from contactor suction motor)Starting of deceleration time through current transformer STWA 1/STWA1H at Z0/Z1 (e.g. L1 from suction motor)adjustable deceleration time 5...30 min.Relay K1: continous vibration 20 s or impulsevibration 18 s with 3 s clockRelay K2: impulse-vibration 40 s with clock 0.5 s or 1.0 s (for magnet valves)LED (yellow) signals deceleration timeLED (green) signals vibration actionautomatic interruption of the vibration action when starting the suction process.Discover the difference between RS1K and RS2K! Type RS1K RS2K Rapping time point Tn after switching on the first machine After Σ(machine runtime) ≥ Tn Tn 1 - 30 min 5 - 30 min Run-down time - 60s Rapping interval K1: for 18s in 3s or continuous vibrating for 20s K1: or 18s in 3s or continuous vibrating for 20s K2: every 0,5s or 0,8s K2: every 0,5s or 1s Display Device power on: - Device power on: LED green Waiting for vibration time: LED red Waiting for vibration time: LED yellow Cleaning active: LED green Cleaning active: LED green flashing Run-down time: - Run-down time: LED yellow flashing Control voltage AC/DC 24 - 240 V AC/DC 24 - 270 V

Bild 1 Netz- und Anlagenschutz UFR1002IP
Voltage and Frequency Relay Type UFR1002IP

NEW: For the German regulation "NELEV" and "EAAV"The Grid and Plant Protection Relay UFR1002IP is the "big brother" of the UFR1001E and monitors voltage and frequency in three-phase and AC grids.With a color LCD display (German/English) and joystick, it is even easier to operate than the UFR1001E. Measured values and settings are clearly displayed. The device can be programmed, updates installed and the alarm memory read out via the integrated IP interface. The real-time clock (with power reserve) simplifies the traceability of the alarms. Up to 1,200 V can be monitored in conjunction with the VG1200 coupling device. The device has a two-channel, single-fault-safe design and thus meets the requirements of VDE-AR-N 4105:2018-11. The function of the connected switch is monitored. If monitoring is activated, the device does not switch on again if a switch-off error is detected.Limit values for different applications are preset. Where permitted, they can easily be changed. If the nominal voltage is changed, the device automatically adjusts the limit values. With the standby input, a remote shutdown can be implemented, e.g. with a ripple control receiver. ZIEHL devices neatly integrated into control panels and control cabinet doors with our installation frames type ER! More information here Monitoring ofUnder/over voltage 15-520V (with ZIEHL VG1200 coupling device up to 1,200 V)Under/over frequency 45-65 HzVoltage quality (10-minute average)Vector shift 2-65°ROCOF, rate of change of frequency df/dt 0.100...5.000 Hz/sZero voltage U0 (ANSI 59v0)passive anti-islanding protectionFeatures:single-fault-proof, with monitoring of connected switch (can be switched off when using the integrated switch of PV and battery convertersProgrammable restart attempts in the event of a switch-on error in the connected switchRelay K3 with programmable functions, including life contact, delayed switch-on signal for switches or error messagesResponse time adjustable 0.05 … 300,0 sSwitch-back time adjustable 0 … 6,000 sPreset according to VDE-AR-N 4105-2018-11 (Pr 1.02, Pr 1.08 + 1.09) and VDE-AR-N 4105-2011-08 (Pr 1.01)Preset according to VDE-AR-N 4110-2018-11 (Pr 1.11-1.14) and bdew guideline (Pr 1.03-1.06)automatic adjustment of the switching points when the nominal voltage is changedAlarm counter for 100 alarms (with trigger value, cause and date/time, time of restart)3 programmable digital inputsStandby counter and timer with standby on/off date/timeTest and simulation function with measurement of switch-off timesSealing option and code protection for settingsInterface ethernet TCP/IP, values available via modbus TCPSimple commissioning and programming thanks to preset basic programs and transmission via IP interfaceSupply voltage AC/DC 24-270 VHousing for DIN-rail-mount, 105 mm wide, mounting height 66 mmAccessory: Installation frame ER6 for panel mount

Bild 1 Universal-Relaisbox Typ URB40
Universal Relay Box Type URB40

Relay extension box type URB40, for universal relay box type URThe URB40 universal relay box is an extension box for UR devices that can be used to control up to four additional relay outputs via Modbus RTU. The URB40 monitors the communication between the devices and can transfer each relay output to a predefined state in the event of a timeout. The device has no operating elements and is controlled and configured exclusively via the RS-485 interface.Accessory: Installation frame ER4 for panel mount ApplicationsWith the URB40, an additional four alarms and relays are available, and the device can also be easily operated on other control systems via the integrated RS 485 interface.4 additional alarmsEasy extension of existing control systems of the UR seriesSpace-saving installation

Bild 1 Pav,e-Überwachung Typ EFR4002IP
Zero Export Device Type EFR4002IP

Energy Flow Relay EFR4002IP – PAV,E Monitoring and Zero Export for Photovoltaic Systems The EFR4002IP energy flow relay from ZIEHL monitors the power flow between the public electricity grid, the power generation system and the consumers at the grid connection point. It enables certified PAV,E monitoring in accordance with VDE-AR-N 4105:2018-11 and supports zero-export applications. As the successor to the EFR4001IP, the EFR4002IP is suitable for monitoring and controlling photovoltaic systems and other power generation installations. As an energy flow direction sensor (EnFluRi), it detects the direction of power flow between the generation system, consumers and the public electricity grid.Operation and configuration are carried out via the integrated web server over Ethernet or directly on the device using the LCD text display. Measured values are clearly displayed. PAV,E Monitoring and Zero Export The EFR4002IP monitors the power flow at the grid connection point and helps ensure compliance with the permitted feed-in power. Under the applicable conditions, this can allow additional generation capacity to be installed, provided that any energy exceeding the permitted feed-in power is consumed on-site rather than exported to the public electricity grid. The device is also suitable for zero-export applications, where no energy may be fed into the public electricity grid. Data exchange with a Power Plant Controller (PPC) is possible. Functions and Benefits PAV,E monitoring: Monitoring of feed-in power at the grid connection point in accordance with German standard VDE-AR-N 4105:2018-11. Disconnection of the generation system: If the permitted feed-in power is exceeded, the entire generation system or part of it can be disconnected via relay K3. Preventive control: Consumers can be switched on or generators curtailed before the permitted feed-in power is exceeded. The analog output and relays K1 and K2 are available for this purpose. Self-consumption optimization: Excess energy generated on-site can be used by selectively switching on consumers. Zero-export operation: Monitoring and control of power flow to prevent energy from being exported to the public electricity grid. Functions for Self-Consumption Optimization Switching of up to three consumers, individually prioritized or in combination with a total of seven switching levels. Adjustable switch-on and switch-off thresholds depending on the measured power flow. Adjustable switch-on and switch-off delays, as well as minimum switch-on times. Control of heat pumps with an SG Ready interface, battery chargers and inverters. For applications using Rogowski coils with a 333 mV measuring input, please refer to our EFR4002IPR. Additional Applications Suitable for medium-voltage applications. Connection of earthed medium-voltage current transformers. Support for connecting multiple measuring devices in series to a single current transformer set. Zero-export operation will also be supported in accordance with German standard VDE-AR-N 4105:2026-03 in the near future. Suitable for applications involving the requirements of the German NELEV and EAAV regulations. Suitable Current Transformers The EFR4002IP can be used with standard current transformers with secondary currents of 1 A or 5 A. For PAV,E monitoring, a minimum accuracy class of 1 is required. Current transformers up to 6,000 A: Standard current transformers, such as ZIEHL current transformers type AS and type WS. Compact current transformer CTM7: Compact current transformer with a ratio of 64/1 A, accuracy class 1 and 0.5 VA. Installation and Accessories ZIEHL installation frames type ER allow devices to be neatly integrated into control panels and control cabinet doors. More information about installation frames type ER

Bild 1 Universal-Relais Typ UR420IP
Universal Relay Type UR420IP

Web-IO universal limit value relay with Ethernet interface, built-in web server and 4 inputs for temperature sensors or other analog signals. The UR420IP can be connected to the internet or an intranet and operated via TCP/IP from a normal PC with a suitable browser.The device can simultaneously evaluate and monitor up to 4 different input signals. Each of the 2 output relays can be assigned up to 4 limit values, one per input. If a limit value is reached, an alarm is triggered and a relay switches. Example: Alarm 1 is activated when a temperature is exceeded at sensor input 3 (e.g. Pt 100) or the signal from a pressure transmitter (e.g. 4-20 mA) at input 5 falls below a limit value. The device also has an RS485 interface (Modbus RTU) that can be used to connect current sensors type STWA4MH and the relay box type URB40.Expandable by 4 additional relay outputs with the URB40! ZIEHL devices neatly integrated into control panels and control cabinet doors with our installation frames type ER! More information hereAccessory: Installation frame ER6 for panel mount ApplicationsThe UR420IP is used where one or more of the following features a required:monitor up to 4 different analogue measured values and transfer them to the InternetMeasured value query and remote maintenance via intranet/internet Discover the difference between our UR-series! Type UR420IP UR840IP Sensors PT100, PT1000, KTY83, KTY84, thermocouples, 0-10V, 0/4-20mA PT100, PT1000, KTY83, KTY84, thermocouples, 0-10V, 0/4-20mA Sensor inputs 4 8 Digital inputs 2 4 Outputs 2x alarm relays 4x alarm relays, 1x analog Alarm types Sensor-specific thresholds, difference, rate of change temperature, 2 out of X Sensor-specific thresholds, difference, rate of change temperature, 2 out of X Virtual sensors 4 8 Display Display, LED Display, LED Configuration Joystick, web interface Joystick, web interface Network / Communication RS485, Ethernet RS485, Ethernet Other functions On/off delay, simulation, expansion with URB or STWA4MH On/off delay, simulation, data visualization, expansion with URB or STWA4MH Housing V6 V8 Applications Measurement monitoring and control Measurement monitoring and control

Bild 1 Schiebermodul Typ STW168M, 8-fach mit Busansteuerung
Slider Module Type STW168M

Bus module for controlling sliders in extraction systemsSTW168M and STW161M shutter modules control up to 8 shutters in extraction systems in conjunction with an STW164IP control unit. Up to 4 STW168M units can be combined with one STW164IP control unit. They are simply mounted next to the STW164IP in the control cabinet. Alternatively, they can be placed near the slide valves. In this case, the module only needs to be connected with one bus cable. The long supply lines to the sliders from the control cabinet are no longer required. At the same time, it is possible to use single modules STW161M in the same system (sliders on STW161M only DC 24 V).Function and propertiesModule for connecting up to 8 slidersOutputs potential-free changeover contacts for 24 or 230 VInputs for detecting the operating status of the machines (on/off), response threshold 0.5...9.9 A adjustable on the STW164IPControl via STW164IP (max. 4 x STW168M can be connected)Bus address 0...31 adjustableControl voltage DC 24 V (via 4-pole bus cable)LEDs for input and output statusesConnections via screw terminalsMounting Distribution board installation on top-hat rail EN60715Dimensions W x H x D: (without screw connections) 94 x 130 x 57 mmAccessories: ER6 mounting frame for panel mounting

Bild 1 Vorschaltgerät Typ VG1200
Coupling Device for Voltage Type VG1200

In order to achieve higher efficiencies and to reduce line losses, inverters with a higher output voltage than the usual 3AC 400 V are often used in large on-site generation systems.So that the grid and system protection can monitor this high voltage, it must be reduced. This is usually done with voltage converters. With the VG1200 coupling device, an ohmic voltage divider is available that takes on this task. In conjunction with the VG1200 coupling device, the UFR1002IP can measure voltages of up to 1200 V. The display in the UFR1002IP is scalable. This means that the voltages at the input of the VG1200 are displayed and the limits for protection against over- and undervoltage are set accordingly. Both devices together meet the requirements of VDE-AR-N 4110 (feeding into the medium-voltage grid).Measuring of voltage up to 1200 VMeasuring tolerance = 1,2% of nominal voltage (of UFR1002IP)No voltage converters requiredDisplay of the correct voltage on the UFR1002IP (scalable)No supply voltage requiredHousing V6, 105 mm wide 

Bild 1 Pav,e Überwachung Typ EFR4002IPR
Zero Export Device Type EFR4002IPR

NEW: Our EFR4002IPR, specifically for the use of Rogowski coils Measuring input: 333mV for Rogowski coilsEnergy flow direction sensor and feed-in limitation, Trigger time less than 0.05sZero-Export device or Limiter less than 0.2 sPPC (Power Plant Controller) -compliant communication Zero feed-in will soon also be possible according to the German standard VDE 4105:2026-03 Zero Export Device and Energy Flow Relay, optimization of self-consumption of self generated energy. Zero feed-in will soon also be possible according to the German standard VDE 4105:2026-03 Our relays for energy flow measurement type EFR4002IPR monitor the current flow between public power grid and generating plant / consumer. Operation is made comfortably via integrated webserver or directly at the device. Measured values are displayed neatly arranged at device on monitor. When the own power plant generates more power than actually is consumed it often is more economical to consume the excess energy self. This is especially reasonable when the difference is high between the price you pay to the grid provider and the price the provider pays for fed in energy.Many areas suitable for photovoltaics could not be used so far, since only a limited amount of power can be fed in at the grid connection point. In Germany new standards VDE-AR-N 4105:2018-11 allow exceeding this value by up to 66.6% or more installed capacity. The prerequisite for this is that the overbuilt power is consumed and not fed into the grid. In order to still ensure the stability of the system, this can be monitored with EFR4002IPR. The same applies to zero export, when no energy at all may be fed into the grid. In this case, the device can be used as an energy flow direction sensor (EnFluRi). The EFR4002IPR has been optimized for these functions.Data exchange with PPC (Power Plant Controller) possible.Functions:Switching of up to 3 consumers: the largest consumer, ranked 1-2-3 or combination of 3 consumers (7 levels)Switch on and off points. At which energy flow consumers are switched on and off againSwitch on and off delay of consumers, minimum on time.Control of heat pumps (SG-ready), battery chargers, inverters ZIEHL devices neatly integrated into control panels and control cabinet doors with our installation frames type ER! More information here  

All products

All products

Filter

Bild 1 Kaltleiter-Relais Typ MSF220K

PTC-Relay type MSF220K

PTC-relay for the monitoring of dry transformers. Alarm 1 with relay in closedcircuit current mode for preliminary warning, releases at over-temperature at PTC-set 1 and serves at the same time as functional monitoring. Alarm 2 in operating current mode. Thus no wiping signal occurs when switching on the supply voltage on. Additional terminals enable comfortable wiring from supply voltage to relays K1 and/or K2.Changes from T221717 / T221718 to T228143 / T228144: Version with spring terminals RoHS/REACH compliantFurther information can be found in our customer information: "New terminals for K-type devices"Changes from T221715 / T221716 to T221717 / T221718: cURus, monitoring of sensors for short circuit an interrupt activatable, improved test functionFunctions2 PTC resistor sets2 output relays 1 change-over contact (co)/ 1 normally open contact (no)monitoring of sensors for short-circuit and break activatableTEST-button (delayed)LEDs for ON, alarm 1 and 2red LEDs for alarm 1 and alarm 2K-type housingHousing for mounting on DIN-rail 35 mm or wall-mount with screws M4Replacement for foreign device Elbag/Joppich TS-01 

Bild 1 Rogowskispule NRCM

Rogowski Coil NRCM

The NRCM Rogowski coils enable precise measurement of AC currents over a wide measuring range. The coil detects alternating currents non-invasively via the magnetic field around the conductor and converts this into a corresponding output voltage. Thanks to the bayonet lock, the coils can be easily retrofitted into existing installations. The Rogowski coil has an accuracy class 1 and a rated impulse withstand voltage of up to 4000 V.3 Rogowski coils are required to operate the EFR4002IPR.

Bild 1 Niveaurelais Typ NS43

Level Relay Type NS43

The level monitor NS43 regulates the level of liquid in a container between 2 electrodes. In the normal operation the level of the liquid is situated between the electrodes E2 and E3. The relay K2 tightens, if the level E3 is achieved and drops, if E2 is fallen below. Over the output contacts (1 change-over switch) a pump or a valve can be controlled depending upon case of application and so the level be regulated.If the level continues to rise in an incident and if the electrode achieves E4, then a message takes place via relay K3 (drops). In the reverse case (level under E1) the relay K1 drops and protects e.g. a pump against running dry. LEDS signal, which electrodes are moistened.Level monitoring of leading liquidsMIN/MAX level regulationprotection from overflowprotection from running drysensitivity adjustable 5...250 kOLED for level display / alarmApplicationIn the galvanotechnics and everywhere, where the level of a leading liquid must be held on a certain level and at the same time a monitoring on overflow and/or no-load operation is necessary.

Bild 1 Universal-Messumformer Typ MU2000K

Universal Measuring Transducer Type MU2000K

Measuring transducers MU2000K can measure DC- an AC-voltages up to 600 V and DC- and AC-currents 0-1/5 A.Preset measuring ranges can be selected. More measuring ranges (zero and full-scale) can be easily scaled. The output signals DC 0/2-10 V and 0/4-20 mA are insulated from measuring input and supply voltage. With its universal supply voltage AC/DC 24-240 V the measuring transducer can be connected to all common supply voltages.The MU2000K e.g. is suitable for measuring DC voltages and charging currents at batteries or for measuring AC voltages and currents in plants for own generation of energy.Changes from T236053 to T236056: Version with spring terminals RoHS/REACH compliantFurther information can be found in our customer information: "New terminals for K-type devices"Overview of functionsOutput signal 0-20mA and 0-10V or 4-20mA and 2-10VRated Supply Voltage AC/DC 24-240VInsulation between inputs, outputs and supply voltage (3-way isolator)InputsAC/DC 0 … 600 V (preset values: 0…30 V / 80…120 V / 0…150 V / 0…300 V / 0…600 V)AC/DC 0 … 5 A (preset values: 0…1 A / 0…5 A)In measuring ranges for AC also DC-signals can be measured. Negative signals will be measured as positive signals.Zeros and Full Scales for more measuring-ranges can be freely selected by the user. Discover the difference between our MU series! Type MU1000K MU1001K MU2000K Measuring values 0/4…20 mA, 0–10 V, PT100 0…±60/150/300 mV DC, 0…±10/300 V DC 0…30/150/300/600 V AC/DC, 0…1/5 A AC/DC Output signals 0/4…20 mA, 0/2–10 V 0/4…20 mA, 0/2–10 V 0/4…20 mA, 0/2–10 V Scaling adjustment 2 buttons: programs or signal calibration 2 buttons: programs or signal calibration 2 buttons: programs or signal calibration Display LEDs 1× Power, 3× Setting 1× Power, 3× Setting 1× Power, 3× Setting Test voltage between potentials 3540 V 3540 V 3540 V Input resolution 14 bit 14 bit 14 bit Output resolution 11.6 bit: < 3.1 mV; < 6.1 µA 11.6 bit: < 3.1 mV; < 6.1 µA 11.6 bit: < 3.1 mV; < 6.1 µA Housing type K K K Measuring time Voltage/current: < 20 ms;Temperature: < 350 ms < 20 ms Adjustable measurement time Main areas of application Signal isolation Signal conversion, voltage measurement Voltage and current measurement

Bild 1 TR640IP, Temperaturrelais für Pt 100/1000, PTC 6 Sensoren, 4 Limits, TCP/IP

Temperature Relay Type TR640IP

Temperature Relays TR640IP monitor up to 6 sensors for up to 4 limits. Different sensors can be connected at the same time, e.g. Pt 100 (RTD) and PTC thermistors. Typical applications are monitoring of motors, generators or transformers. An other application is the use as a two or more step controller with additional monitoring of over- or undertemperature or monitoring of differences in temperatures of 2 sensors.Preset programs allow easy setting e.g. monitoring of transformers with/without monitoring of temperature of core or with/without controlling a ventilator.If evaluation "2 out of x" is activated with several connected sensors, an alarm is only triggered when the limit value is exceeded in 2 sensors. This prevents false alarms due to a fault in one sensor. Operation can be made at the device or with a standard browser via Ethernet.6 inputs for sensors Pt 100, Pt 1000 and PTC, mixed sensors possible4 alarms / relay outputsalarm 2 of x = alarm only when limit is exceeded in min. 2 sensorsmonitoring of difference of temperaturesmonitoring of rate of change of temperaturelogging of temperatures and historypreset programs for protection of motors, transformers and moreinterface ethernet TCP/IP, values available via modbus TCPprogramming with browser via TCP/IP or with joystick at devicecoloured LED display for clear display of temperatures and states of alarmsuniversal power supply AC/DC 24-270 VAccessory: Installation frame ER6 for panel mount ZIEHL devices neatly integrated into control panels and control cabinet doors with our installation frames type ER! More information here Discover the difference between our TR640IP, TR660IP and UR840IP! Type TR640IP TR660IP UR840IP Sensors PTC, Pt100, Pt1000 PTC, Pt100, Pt1000 Pt100, Pt1000, KTY83, KTY84, thermocouples, 0-10V, 0/4-20mA Sensor inputs 6 6 8 Digital inputs - - 4 Outputs 4x alarm relays 6x alarm relays, 2x analog (only T224370) 4x alarm relays, 1x analog Alarm types Limit value, differential, rate of change of temperature, 2 out of x Limit value, differential, rate of change of temperature, 2 out of x Sensor-specific limit values, differential, average, min/max, 2 out of x Virtual sensors - - 8 Display Display, LED Display, LED Display, LED Network / Communication Ethernet RS485 (only T224371), Ethernet RS485, Ethernet Other functions On/off delay, simulation, cyclic relay test, 2 digital inputs On/off delay, simulation, cyclic relay test, 2 digital inputs On/off delay, simulation, expansion with URB or STWA4MH Housing V6 V8 V8

Bild 1 Kaltleiter-Relais Typ MSR220VA

PTC-Thermistor-Relay Type MSR220VA

Ziehl PTC thermistor relays protect motors, transformers, machines and equipment against thermal overload. These are according to DIN EN 60947-8 and are thus exchangeable. Used in conjunction with respective PTC thermistors they provide a reliable temperature protection in the temperature range 60 °C up to 180 °C. The device is conform to EN IEC 60947-8. Thermistors according to DIN VDE V 0898-1-401 (ATEX) or equivalent detail specification (UKEX) shall be connected. PTC thermistors are suitable for the installation into windings of electrical machines, bearings and transformers as well as to monitor the temperature of liquid media, airflow and gases. With ATEX approval, explosion-protected equipment in explosive gas atmospheres (marking G: gas) or in areas with combustible dust (marking D: dust) can be protected.FeaturesATEX directive 2014/34/EU1 circuit for 1, 3 or 6 PTC thermistorsShort-circuit detection within the thermistor circuitOutput relay with 1 change-over contact (co)Operating status display with LEDelectronic reclosing lock (disconnectable)integrated RESET-buttonlink for external RESETautomatic RESET at voltage recoveryOperating status display with LED 

Bild 1 Stromrelais Typ STW81V

Current relay Type STW81V

The basic function of the device is to detect whether a current is flowing in the supply line of one of several woodworking machines. If a current flow is detected, the device opens a valve on the machine's suction channel. At the same time, the extraction system is switched on. When a machine is switched off, the device closes the associated valve with a delay. If the last machine is switched off, the extraction system also stops after a delay.The current relay STW81V is an 8-channel AC current relay, designed for controlling of suction plants e.g. in the timber and plastics processing industry. When there is an AC-current >1A through one of up to 8 connected transformers type STWA1, the appropriate relay K1...K8 (1 x co) picks up and opens the slide valve of the machine. At the same time the relay K9 starts the central suction.Relays K1...K8 switch off 10s after the current flow through the appropriate transformer is 0. K9 switches off 0...60s (adjustable) after the current in all transformers is 0.ApplicationThe current relay STW81V is particularly suitable for the central control of slide valves in suction plants, which are to be operated dependent on operating condition of individual machines. It can control a central suction at the same time.single evaluation of 8 inputs with STWA1single evaluation of 8 inputs with current-sensor S1inputs for 8 potential-free contactsOR-evaluation of all circuits (K9)9 output relaysLED display for relays / inputsSwitching point adjustable 0,5 - 5 Aswitch-off delay of K9 adjustable 0 - 60 secondsswitch-off delay single relays 10 slast relay: K9 + 20 s

Bild 1 Drehrichtungsrelais Typ DRR10

Phase-Sequence Relay Type DRR10

Phase-sequence relays DRR10 measure the sequence of the phases when being switched on and switch - if necessary - the rotation of the field by changing 2 phases.The integrated PTC-monitor protects the motor from overheating.Applications are especially machines and equipment, that is operated at variable locations e.g. at building sites. Pumps, compressors and vacuum cleaners always run correctly. Nomore search for faults or change of wiring necessary.Overview of Functionautomatic change of wrong phase-sequence when connected falselyrunning backward of motors is avoidedintegrated PTC-protection for motorenable-input for direct switching on/off of the motor with DRR 10max. 3 x 12 Aswitch-on currents 30 A / max. 4 s / 60 A / max. 1 shigher currents with external contactorsintegrated protection for relay contactsintegrated protection from over-temperaturehousing for mounting in fuse-boxes or switchgearcabinets, mounting height 55 mm

Bild 1 Watchdog-Zeitrelais Typ WD100V

Watchdog Time-Relay Type WD100V

In the control technology of today, the number of industrial PCs (IPC) partly with decentralized intelligence constantly increases.Individual processes are controlled independent of each other. In case of failure or malfunction of one component, it can therefore be necessary to switch off the hardware of a complete machine or plant.Time-Relay WD100V is used to make sure that because of malfunctions in the program flow, caused by short-term voltage interruptions for instance, no undefined status are created.Changes Z224317 --> Z224319: input 5V, maximum pulse length up to 10 s, better temperature stabilityOverview of functions:Input-signal 5/24 V DC square waveMinimum pulse length 500 µsMaximum pulse length 10 sMonitoring of positive and negative slopesWatchdog-time = Time x Scale (1 ms-10 s)Display of state of function with LED (Alarm)Reset with external contact or switchUniversal power-supply AC/DC 24-240 VRelay-output (1 change-over contact)

Bild 1 TR210, Grenzwertrelais, 2 Eingänge, Messumformer, Pt 100/1000, KTY, Thermoelemente, 0/4-20 mA, 0-10V

Temperature-Relay TR210

The TR210 is used asGeneral temperature protection of machines and installationsTemperature control unit, also for cooling applicationsDifference temperature controller unit for air-conditioning technologyOverview of functions2 Sensor inputsPt 100, Pt 1000, KTY 83 or KTY 84 in 2- or 3-wire configurationThermocouples Type B, E, J, K, L, N, R, S, TInput signal DC 0-10 V; DC 0/4-20 mA0.1 °C resolution between –199.9...999.9 °C2 Relay outputs (each 1 change-over contact)1 Analogue output DC 0-10 V or 0/4-20 mA for parameterizing (not potentially separated from the inputs)Universal power supply AC/DC 24-240 VSeveral selectable programsStorage and indication of the measured MIN- und MAX-valuespluggable terminalsAccessory: Front mounting kit type ER4Alternative: Temperature relay Type TR640IP

Bild 1 Stromrelais Typ STW1K

Current-Relay Typ STW1K

The automatic start-up system for woodworking machines is a control unit that has been specially developed for the efficient control of extraction systems. Its main function is to monitor the current flow in the supply lines of several machines and to control the extraction system accordingly. Detailed description of the functionality:Current detection: The automatic start-up system is equipped with current relays that monitor the current flow in the supply lines of the machines. These relays are configured in an OR circuit with up to eight inputs. As soon as a current of more than 1 ampere flows through one of the connected current transformers, the built-in relay picks up and activates the extraction system.Automatic control: If at least one machine is switched on and draws current, the extraction system is activated automatically. This ensures that dust and chips are extracted immediately, keeping the working environment clean and safe.Delayed switch-off: As soon as all machines are switched off and no more electricity is flowing, the relay drops out with a delay of around 10 seconds. This delay time allows the extraction system to remove any remaining particles from the air before it is switched off. Typical application: In a joinery that operates several woodworking machines such as saws, planers and routers, the automatic start-up system is installed centrally in the control cabinet. The current transformers are connected to the supply lines of the individual machines. When the carpenter switches on a machine, the automatic start-up system detects the current flow and activates the central extraction system. This ensures that dust and chips produced during woodworking are extracted immediately. As soon as the work is finished and all machines are switched off, the extraction system remains active for a short time to remove the remaining particles before it switches off automatically. This automation not only improves the efficiency of the extraction system, but also contributes to safety and cleanliness in the workplace.8 inputsOR-evaluationrelay picks up if at least 1 input is activatedConnection of current transformers STWA1 or STWA1Hoperating value approx. 1 Aturn-off delay approx. 10 snot necessary inputs remain open  Change S225636 -> S227400: Our alternative for the STW1K AC220-240V (S225636) is the new STW1K with wide-range power supply unit AC/DC 24-270V (S227400). Version with spring-loaded terminals RoHS/REACH-compliant. Further information can be found in our customer information: “New terminals for type K devices”. The S227400 is an alternative with minor deviations.If you have any questions, please contact our sales department: +49 791 504-103, verkauf@ziehl.de

Bild 1 TF101R, Sensor Pt 100, -20...+ 70 °C, Raumtemperatursensor 60x60x38 mm

Pt100-Temperature-Sensors Type TF101R

TF101 temperature sensors use EN 60751/IEC 60751 platinum resistance temperature detectors (RTD). For precise temperature measurement the Platinum Resistance Thermometer offers the best overall advantages in repeatability and stability over a long period. High accuracy allows replacement of a sensor without any need for re-adjust of the connected measuring devices or thermostats. TF101 temperature sensors are available in different designs.Sensor for measuring ambient temperatures inside or outside. Protection class IP 54. Cabling can be connected in 2- or 3- wire technique.

Bild 1 TF101U2, Sensor Pt 100 Bauform U2

Pt100-Temperature-Sensors Type TF101U2

TF101 temperature sensors use EN 60751/IEC 60751 platinum resistance temperature detectors (RTD). For precise temperature measurement the Platinum Resistance Thermometer offers the best overall advantages in repeatability and stability over a long period. High accuracy allows replacement of a sensor without any need for re-adjust of the connected measuring devices or thermostats. TF101 temperature sensors are available in different designs.Platinum resistance temperature sensor on ceramic substrate intended for installation into any housing depending to user’s requirements. Very small and quick sensor, only suitable for further treatment. Notice: do not cut the sensor leads. Thermal response time refer to manufacturer data: T0,9 in the air 10 s, in water <1 s.Weight:PVC: 2m = 50g, 10m = 250, 30 mm = 15gPTFE: 2m = 20g

Bild 1 Kaltleiter-Relais Typ MSF220SE

PTC-relays Type MSF220SE

The PTC-resistor trip device MSF220SE monitors the winding temperature of machines and equipment. Signals, that can be used as ”early warning" or ”malfunction" (switching-off), are transmitted as soon as the admissible limit temperature is exceeded.Two PTC-circuits can be connected to this unit. The integrated rise-delay time ensures a reliable mains voltage build-up.Function2 PTC resistor circuits, 1 to 6 PTC each (max. cold resistance of circuit 1500O each)potential-free contact for alarm 1potential-free contact for alarm 2voltage of pin 3 is connectet to pin 1 with a time delay of 2 sec., replacing an additional timing relay.alarm 3 for check of relay K3LED´s signal state of relays K1 and K2relay K3 picks up time-delayedTEST-button for ALARM 1 and ALARM 2NoteThanks to the delayed switching-on of the error message (approx. 2 s) after the switching-on, this device is especially suitable where an auxiliary voltage is not available and the secondary voltage of the monitored transformer is being used. The MSF220SE can furthermore be used advantageously when combining it with operating current releases. For additional devices, the control voltage is available at terminal 1 time-delayed. In case of a breakdown of the supply voltage, the control voltage is available at terminal 7 and can be used as a message. (Attention! This message will also be given for approx. 2 s. after switching-on.)Functional descriptionPTC-circuits in closed-circuit current principle. When the closed-circuit current flows, both output relays K1, K2 are picked up. Approx. 2 sec. after switching on supply power, relay K3 picks up time-delayed, closing the contact circuits at terminals 31, 14 and 31, 24. As soon as the temperature of the early warning has been reached, relay K1 releases (terminal 31, 12 closed), the alarm 1 is given. If the temperature of malfunction is reached, also relay K2 releases (terminal 31, 22 closed). This alarm 2 can be used to switch off the equipment. If the temperature drops to approx. 5 °C below the temperature of malfunction or early warning, the relays K1 and K2 resp. are switched on again.TEST: LED "ON" – flash -> +2 s -> Alarm 1 -> +3 s -> Alarm 2 

Bild 1 proQuick Montageschelle

proQuick Mounting Kit

Mounting kit for current transformers type STWA1 and type STWA1S for secure installation. These heavy-duty clamps enable universal mounting on walls, ceilings, or steel structures, both indoors and outdoors. The flexible clamping range allows for tool-free installation and connection in series up to Ø 32 mm, even in combination with OBO Quick or Multi-Quick clamps. For the STWA1 and STWA1S from ZIEHL, the mounting kit offers a stable and versatile mounting option.Your advantages:Quick, tool-free assembly for efficient installation Universal mounting on walls, ceilings, and steel structuresFlexible clamping range (31,2 mm - 35,5mm)Sturdy and corrosion-resistant for indoor and outdoor useCompatible with OBO Quick and Multi-Quick clamps Versatile mounting options for the STWA1 and STWA1S from ZIEHL

Bild 1 Pav,e Überwachung Typ EFR4002IPR

Zero Export Device Type EFR4002IPR

NEW: Our EFR4002IPR, specifically for the use of Rogowski coils Measuring input: 333mV for Rogowski coilsEnergy flow direction sensor and feed-in limitation, Trigger time less than 0.05sZero-Export device or Limiter less than 0.2 sPPC (Power Plant Controller) -compliant communication Zero feed-in will soon also be possible according to the German standard VDE 4105:2026-03 Zero Export Device and Energy Flow Relay, optimization of self-consumption of self generated energy. Zero feed-in will soon also be possible according to the German standard VDE 4105:2026-03 Our relays for energy flow measurement type EFR4002IPR monitor the current flow between public power grid and generating plant / consumer. Operation is made comfortably via integrated webserver or directly at the device. Measured values are displayed neatly arranged at device on monitor. When the own power plant generates more power than actually is consumed it often is more economical to consume the excess energy self. This is especially reasonable when the difference is high between the price you pay to the grid provider and the price the provider pays for fed in energy.Many areas suitable for photovoltaics could not be used so far, since only a limited amount of power can be fed in at the grid connection point. In Germany new standards VDE-AR-N 4105:2018-11 allow exceeding this value by up to 66.6% or more installed capacity. The prerequisite for this is that the overbuilt power is consumed and not fed into the grid. In order to still ensure the stability of the system, this can be monitored with EFR4002IPR. The same applies to zero export, when no energy at all may be fed into the grid. In this case, the device can be used as an energy flow direction sensor (EnFluRi). The EFR4002IPR has been optimized for these functions.Data exchange with PPC (Power Plant Controller) possible.Functions:Switching of up to 3 consumers: the largest consumer, ranked 1-2-3 or combination of 3 consumers (7 levels)Switch on and off points. At which energy flow consumers are switched on and off againSwitch on and off delay of consumers, minimum on time.Control of heat pumps (SG-ready), battery chargers, inverters ZIEHL devices neatly integrated into control panels and control cabinet doors with our installation frames type ER! More information here  

Bild 1 Universal-Messumformer Typ MU1000K

Universal-Measuring-Transducer Type MU1000K

Universal-measuring-transducers MU1000K can measure signals Pt100 (RTD) and DC current (0/4-20 mA) and voltage (DC 0/2-10 V). Several measuring-ranges are pre-programmed. More can be easily scaled. Temperatures at sensors Pt 100 can be evaluated from -200 °C to + 800 °.The output-signals 0/2-10 V and 0/4-20 mA are potentially separated from inputs and supply voltage. With its universal power-supply AC/DC 24-240 V the measuring transducer can be connected to all common supply-voltages. It can be used as an isolating amplifier for 0-10 V signals.Overview of functionsCurrent input 0-20mA, scalableVoltage input 0-10V, scalableInput Pt 100, 3-wire, -200…+800 °C, scalableOutput signal 0-20mA and 0-10V or 4-20mA and 2-10VRated Supply Voltage AC/DC 24-240VInsulation between inputs, outputs and supply voltage (3-way isolator)Standard ranges adjustable, universally scalable input ranges Discover the difference between our MU series! Type MU1000K MU1001K MU2000K Measuring values 0/4…20 mA, 0–10 V, PT100 0…±60/150/300 mV DC, 0…±10/300 V DC 0…30/150/300/600 V AC/DC, 0…1/5 A AC/DC Output signals 0/4…20 mA, 0/2–10 V 0/4…20 mA, 0/2–10 V 0/4…20 mA, 0/2–10 V Scaling adjustment 2 buttons: programs or signal calibration 2 buttons: programs or signal calibration 2 buttons: programs or signal calibration Display LEDs 1× Power, 3× Setting 1× Power, 3× Setting 1× Power, 3× Setting Test voltage between potentials 3540 V 3540 V 3540 V Input resolution 14 bit 14 bit 14 bit Output resolution 11.6 bit: < 3.1 mV; < 6.1 µA 11.6 bit: < 3.1 mV; < 6.1 µA 11.6 bit: < 3.1 mV; < 6.1 µA Housing type K K K Measuring time Voltage/current: < 20 ms;Temperature: < 350 ms < 20 ms Adjustable measurement time Main areas of application Signal isolation Signal conversion, voltage measurement Voltage and current measurement

Tip
Bild 1 Einbaurahmen Typ ER

Front Mounting Kit Type ER

You found a device in that meets your requirements and you want to install it in a control panel or in the door of a control cabinet?With the installation frame of the ER series, this is possible for all ZIEHL devices in housings V4, V6 and V8 (width 70/105/140 mm).Enclosed by a high-quality frame made of anodized aluminum, all displays can be read outside the control cabinet. Switches, buttons and joystick can be operated. 

Bild 1 Drehrichtungsrelais Typ DRR20

Phase Sequence-Change Relay DRR20

Phase-Sequence-Change Relays DRR20 measure the sequence of the phases and switch – if necessary the rotation of the field. At the output (connect relays K1 and K2 in series in this application) two contactors are connected. The contactor at the normally-open contact of K2 switches the phases 1:1without changing them, the second (atnormally-closed contact) changes 2 phases.When switching on with phasesequence ok, relay K2 picks up. With wrong phase-sequence it remains released. After K2 has switched, K1 picks up. K1 also releases first. This makes sure, that no wrong contactor can be picked up under any condition. Additionally the DRR20 monitors the three phases for asymmetry and undervoltage. If the limits are exceeded, the K1 switches off (respectively doesn't pick up) and protects the connected motor from damage. The device can also be used as a monitor for undervoltage, asymmetry or phase-sequence.Applications are machines and equipment that is operated at variable locations, e.g. at building sites. Pumps, compressors and vacuum-cleaners alwaysrun correctly and they are protected from damage by undervoltage or asymmetry.automatic change of wrong phase-sequence when connected falsely (2 contactors afforded)running backward of motors is avoidedno switching on at asymmetry or undervoltagerelay K2 picks up when phase-sequence is correctrelay K1 picks up (after K2) when symmetry and voltage is correct3 LEDs for state of relays and errorsmeasuring-voltage 3 AC 400 Vlimit asymmetry adjustable 5…25 %limit undervoltage adjustable 70…95 %alarm-delay adjustable 0,1…10 s (undervoltage and asymmetry)no supply-voltage required

Bild 1 Universal-Messumformer Typ MU1001K

Measuring-Transducer Type MU1001K

Universal Measuring-Transducers MU1001K can measure DC-signals up to 300 V. Inputs 60/150/300 mV measure direct current. Pre-set measuring-ranges can be selected by the user. More measuring-ranges (zero and full scale) can be easily scaled. The output-signals DC 0/2-10 V and 0/4-20 mA are insulated from measuring-input and supply-voltage.With its universal power-supply AC/DC 24-240 V the measuring-transducer can be connected to all common supply-voltages. It can be used as an isolating amplifier for 0-10 V signals.Overview of functionsOutput signal 0-20mA and 0-10V or 4-20mA and 2-10VRated Supply Voltage AC/DC 24-240VInsulation between inputs, outputs and supply voltage (3-way isolator)Standard ranges adjustable, universally scalable input rangesInputsDC -300 … 300 mV (preset values: 0…60 / 0…150 / 0…300 / -60…60 / -150…150 / -300…300 mV)DC -10 … 10 V (preset values: 0…10 / 2…10 / -10…10 V)DC 0 … 300 V (preset values: 0…20 / 0…50 / 0…100 / 0…200 / 0…300 V)Zeros and Full Scales for more measuring-ranges can be freely selected by the user.Changes from T236006.1 to T236017: Version with spring terminals RoHS/REACH compliantFurther information can be found in our customer information: "New terminals for K-type devices" Discover the difference between our MU series! Type MU1000K MU1001K MU2000K Measuring values 0/4…20 mA, 0–10 V, PT100 0…±60/150/300 mV DC, 0…±10/300 V DC 0…30/150/300/600 V AC/DC, 0…1/5 A AC/DC Output signals 0/4…20 mA, 0/2–10 V 0/4…20 mA, 0/2–10 V 0/4…20 mA, 0/2–10 V Scaling adjustment 2 buttons: programs or signal calibration 2 buttons: programs or signal calibration 2 buttons: programs or signal calibration Display LEDs 1× Power, 3× Setting 1× Power, 3× Setting 1× Power, 3× Setting Test voltage between potentials 3540 V 3540 V 3540 V Input resolution 14 bit 14 bit 14 bit Output resolution 11.6 bit: < 3.1 mV; < 6.1 µA 11.6 bit: < 3.1 mV; < 6.1 µA 11.6 bit: < 3.1 mV; < 6.1 µA Housing type K K K Measuring time Voltage/current: < 20 ms;Temperature: < 350 ms < 20 ms Adjustable measurement time Main areas of application Signal isolation Signal conversion, voltage measurement Voltage and current measurement

Bild 1 Stromwandler zur AC-Strommessung Typ AS

Current Transformer for AC-Current Type AS

For currents >5A current monitors require a current transformer with secondary 1 or 5 A and a rated capacity of 1.5 VA. The primary rated current must be appropriate to the max. expected current (fuse). Tube ore wound current transformers can be used.For primary rated currents of 60 to 500 A we recommend using AS tube current transformers, suitable for the Cu-rail of 30 x 10 mm or 2 x 20 x 10 mm or round conductor of 28 mm. The transformers have Class 1 accuracy and a voltage resistance of up to 800 V. When ordering, please indicate desired  primary and secondary rated current. 

Bild 1 Trafoschutz-Temperaturrelais TR440

Transformer Protection Temperature Relay Type TR440

Temperature relay to protect transformers against excess temperature and to control a fan.The temperatures in the windings are monitored with three Pt 100 sensors. The core temperature can be monitored with a fourth sensor.The 4 alarms/output relays are used to control the fan, to signal an advance warning and to switch-off the transformer. Various programs facilitate using the alarm ideally for each application. Depending on the program, e.g. an extra relay is available for the fault message or for triggering due to exceeding the maximum core temperature.Other usesAlternatively, with the fourth sensor the temperature of the room the transformer is located in can be monitored and, with the alarm, the room ventilation can be controlled. The device can also be used for other tasks for temperature monitoringe.g., for motors.Overview of the functions4 Sensor inputs Pt 100 (RTD), 2 or 3-wire connectionLarge monitoring range -199…+850°C / -199...+999°F4 Alarms / Relays3-digit digital display (resolution 1°C / 1°F)4 LEDs sensor4 LEDs relay4 LEDs alarm1 LED errorControl voltage AC/DC 24-240 VClear displays and simple programmingMin and max sensor values can be savedCode lock against unintended / unauthorised changes to the settingsOptional RS 485 interface with Modbus RTU protocolEasySimulation for simple sensor value simulation 

Bild 1 Kaltleiter-Relais Typ MSR220K2

PTC-Resistor-Relay Type MSR220K2

ZIEHL PTC-resistor relays protect motors, transformers, machines and equipment against thermal overload. With ZIEHL PTC Sensors MINIKA ® applied they offer best solutions for nominal response temperatures 60°C…180°C.ZIEHL PTC-resistor relays are designed for PTC-sensors according to DIN 44081 and DIN 44082. Therefor sensor and relays are exchangeable. PTC-resistor sensors are suitable for the installation into windings of electrical machines, bearings and transformers as well as to monitor the temperature of liquid media, airflow and gases.Used in conjunction, they provide a effectively and reliable protection in case ofblocking rotors, heavy starts, countercurrent operationundervoltage and phase failureincreased ambient temperature and hindered coolingThe MSR220K2 monitors 2 PTC resistor sets at the same time. If a temperature rise occurs in one set, the appropriate output relay releases. With this relay, 2 PTC-sets can be independently monitored. Functional overview2 PTC-resistor sets, each 1...6 PTC resistors, or bimetal contactsoutput relays 2 x 1 change-over contact (co)LEDs for operation and alarmelectronic reclosing lock (disconnectable)integrated RESET-buttonlink for external RESETautomatic RESET at voltage recoveryUL-Recognized Component  ATTENTION:Replacement item for T221923 AC/DC 24V = T221943: Version with reset functionReplacement item for T221925 AC 230V = T221945: Version with reset function

Bild 1 Niveaurelais Typ NS20

Level Relay Type NS20

Level-Relays NS 20 for conductive liquids can be used as monitors for 1 Level and for controlling a level between 2 electrodes.3 elektrodes for MIN/MAXcontrol2 elektrodes (E2 open) as level monitorSensitivity adjustable 5 kO…250 kOLED for state of relayFunction of relay reversible (picks up or releases at top electrode)Switching-delay adjustable 0,1…10 sHousing 35 mm wide, mounting height 55 mmUniversal supply-voltage AC/DC 24-240 VApplication level monitorProtection from running dry or overflow, monitoring of pumps for leaks, detection of leaks.Application Min/MaxControlling a level between minimum (elektrode E2) and maximum (E3). As long as E3 is dry, a magnetic valve is opened (or a pump is running) and liquid is influenting. As soon as maximum (E3) is reached, the NS 20 closes the valve. When the level falls below E2, the cycle starts new. In reverse also discharging of a container can be controlled.Overview of functions example filling with 2 electrodesThe detection of the level is made with a DC-free measuring of resistance between all electrodes The common electrode in E 1. A magnetic valve that is switched with relay-contacts 15-18 opens and lets liquid in until the upper electrode E3 is in contact with the liquid. Then the relay releases (15-18 open) and the valve closes. The relay remains released as long as electrode E 2 is in contact with the liquid. When the level falls below E2, the relay picks up (LED Relay on, 15-18 close) and the procedure starts new with opening the valve. Thus thelevel of the liquid is kept between E 1 and E 2.For monitoring one level only or in applications to protect from running dry or overflow or leak detection, only electrodes E1 and E3 are connected.