Temperature-Relay Type TR122D(A)
Switching-Relays Typs TR 122 D(A) monitor the input-signal for 2 limits. The TR 122 DA transduces the measured temperature/resistance to a proportional DC-current. Applications of the TR 122 D(A) are:Monitoring of temperatures with pre-alarm and alarm in machines and plantsControlling of temperatures e.g. for heated sample gas lines or refrigerating plantsTransducer for Pt 100 (RTD) and resistance (TR 122 DA only)Overview of Functions1 input sensor, Pt 100 (RTD) or resistanceMeasuring ranges -199...850°C / 0...850 Resolution 0,1 °C / within the ranges -19,9...99,9 °C / 0-99,9 2 relay outputs (each 1 change-over contact)1 analog output 0/4-20 mA scaleable (TR 122 DA only, not potentially separated from the inputs)Universal power supply AC/DC 24-240 VStorage and display of the measured MIN- and MAX-values
Tip
Electronic Current-Transducer Type STWA4MH
STWA4MH is a measuring transducer. It measures AC up to 60A and has an RS485 interface (Modbus RTU). The measured analog current value is made available as a digital signal and can be read by a PLC, an IPC or a master computer.The conductor to be measured is passed through an opening (Ø 11 mm). In case of small currents, the sensitivity of the current transducer can be increased by looping through the current-carrying conductor several times, e.g. double looping doubles the sensitivity. The measuring range of the STWA4MH is reduced by multiple looping. To measure currents of any size, the STWA4MH is simply looped into the secondary circuit of a large current transformer with a secondary output of 5A (lead the cable through STWA4MH several times).Application:The STWA4MH enables the space-saving an cost-effective measurement of the actual value of an alternating current. Compared to transducers with analog output, the bus technology significantly reduces the effort for the hardware (inputs) and the wiring. Applications are e.g. the recording of the current consumption of electrical motors in processing machines. Here the feed can be regulated depending on the load on the motor. Another example is the monitoring of consumers, e.g. heating elements, for failure.
Electronic Current-Transducer Type STWA2AH
The STWA2 AH is a current-transducer for AC currents 0...20/100 A. With the STWA 2 AH the value of a current can be evaluated very economically and space-saving. The output-signal 4...20 mA can be evaluated or displayed with components with analog inputs, e.g. PLCs or ZIEHL digital displays type MINIPAN ®.Overview of Functionscurrent-proportional analog output DC 4...20 mA according to AC-measuring rangemeasuring range (20/100 A) can be changed with bridgeinsulated analog outputsupply DC 9-30 V (via 4-20 mA-loop)electrical connection via screwless pluggable terminalsDIN-rail-mount or with screwsplug-in current transformer (Ø 11 mm)
Electronic Current-Transducer Type STWA1AH
The STWA1AH is a current-transducer for AC currents 0...15 A. With the STWA1AH the value of a current can be evaluated very economically and space-saving.The output-signal 0...20 mA can be evaluated or displayed with components with analog inputs, e.g. PLCs or ZIEHL TR 210, STW 1000 V2 or MINIPAN®.For output-signal 4...20 mA choose our Electronic Current-Transducer Type STWA2AHcurrent-proportional analog output DC 0...20 mA = AC 0...15 A (insulated)electrical connection via screw less pluggable terminalsno supply voltage requiredDIN-rail-mount or with screwsplug-in current transformer (Ø 11 mm)max. overload 100 A continuously, 300 A max. 10 s
AC-Electronic Current Transformer Type STWA1S
The STWA1S has an integrated electronic with transistor-output. The switching point is 2 A. Above app. 2 A the output transistor is switched on (LOW), below app. 1.5 A it is off (HIGH). The conductor is simply pushed through the transformer.Multiple loops reduce the switching point correspondingly, for instance to 0.5 A with four loops. A supply voltage is not required.ApplicationThe STWA1S is used where current flow is to be detected, with the exact value of the current either known from the power consumption of the connected consumer or does not matter for the evaluation.For simultaneous evaluation of the current flow in several conductors the STWA1S device can be connected in series (AND circuit, pay attention to the voltage drop) or in parallel (OR circuit, pay attention to the leak current).isolated transistor-output max. DC 40 V/40 mAoutput can be directly connected to the digital input of a PLCintegrated diode for reverse voltage protection2-wire-connection, 1 mno supply voltage requiredtransformer and electronic unit enapsulated in a climate-proof housingplug-in current transformer (Ø 11 mm)max. overload 100 A continously, 300 A / 10 s
Temperature-Relay TR210
The TR210 is used asGeneral temperature protection of machines and installationsTemperature control unit, also for cooling applicationsDifference temperature controller unit for air-conditioning technologyOverview of functions2 Sensor inputsPt 100, Pt 1000, KTY 83 or KTY 84 in 2- or 3-wire configurationThermocouples Type B, E, J, K, L, N, R, S, TInput signal DC 0-10 V; DC 0/4-20 mA0.1 °C resolution between –199.9...999.9 °C2 Relay outputs (each 1 change-over contact)1 Analogue output DC 0-10 V or 0/4-20 mA for parameterizing (not potentially separated from the inputs)Universal power supply AC/DC 24-240 VSeveral selectable programsStorage and indication of the measured MIN- und MAX-valuespluggable terminalsAccessory: Front mounting kit type ER4Alternative: Temperature relay Type TR640IP
Electronic Current-Transformer Type STWA1SH
The STWA1SH is used where current flow has to be detected, with the exact value of the current either known from the power consumption of the connected consumer or does not matter for the evaluation.The STWA1SH has an integrated electronics with transistor-output. isolated transistor-output max. DC 40 V / 40 mAoutput van be directly connected to a digital input of a PLCintegrated diode for reverse voltage protectionelectrical connection via screwless pluggable terminals2- wire, no supply voltage requiredDIN-rail-mount or with screwsplug-in current transformer (Ø 11 mm)max. overload 100 A continuously, 300 A max. 10 s