Skip to main content Skip to search Skip to main navigation
Go to homepage
Skip product gallery

New products

Bild 1 TR660IP, Temperaturrelais für Pt 100, PT1000, PTC 6 Sensoren, 7 Limits, TCP/IP
Temperature Relay Type TR660IP

Temperature Relays TR660IP monitor up to 6 sensors for up to 7 limits. Different sensors can be connected at the same time, e.g. Pt 100 (RTD) and PTC thermistors. Typical applications are monitoring of motors, generators or transformers. An other application is the use as a two or more step controller with additional monitoring of over- or undertemperature or monitoring of differences in temperatures of 2 sensors.Preset programs allow easy setting e.g. monitoring of transformers with/without monitoring of temperature of core or with/without controlling a ventilator.If the evaluation "2 out of x" is activated with several connected sensors, an alarm is only triggered when the limit value is exceeded in 2 sensors. This prevents false alarms due to a fault in one sensor. Operation can be made at the device or with a standard browser via Ethernet.6 inputs for sensors Pt 100, Pt 1000 and PTC, mixed sensors possible7 alarms / relay outputsalarm 2 of x = alarm only when limit is exceeded in min. 2 sensorsmonitoring of difference of temperaturesmonitoring of rate of change of temperaturelogging of temperatures and historypreset programs for protection of motors, transformers and moreinterface ethernet TCP/IP, values available via modbus TCPprogramming with browser via TCP/IP or with joystick at devicecoloured LED display for clear display of temperatures and states of alarmsuniversal power supply AC/DC 24-270 VAccessory: Installation frame ER8 for panel mountTR660IP RS485:  interface RS485 (modbus RTU)TR660IP analog:  4 analog outputs 2x 0/4 - 20 mA and 2x 0/2 - 10 V, isolated from sensor inputs, individually programmable. 

Bild 1 TR640IP, Temperaturrelais für Pt 100/1000, PTC 6 Sensoren, 4 Limits, TCP/IP
Temperature Relay Type TR640IP

Temperature Relays TR640IP monitor up to 6 sensors for up to 4 limits. Different sensors can be connected at the same time, e.g. Pt 100 (RTD) and PTC thermistors. Typical applications are monitoring of motors, generators or transformers. An other application is the use as a two or more step controller with additional monitoring of over- or undertemperature or monitoring of differences in temperatures of 2 sensors.Preset programs allow easy setting e.g. monitoring of transformers with/without monitoring of temperature of core or with/without controlling a ventilator.If evaluation "2 out of x" is activated with several connected sensors, an alarm is only triggered when the limit value is exceeded in 2 sensors. This prevents false alarms due to a fault in one sensor. Operation can be made at the device or with a standard browser via Ethernet.6 inputs for sensors Pt 100, Pt 1000 and PTC, mixed sensors possible4 alarms / relay outputsalarm 2 of x = alarm only when limit is exceeded in min. 2 sensorsmonitoring of difference of temperaturesmonitoring of rate of change of temperaturelogging of temperatures and historypreset programs for protection of motors, transformers and moreinterface ethernet TCP/IP, values available via modbus TCPprogramming with browser via TCP/IP or with joystick at devicecoloured LED display for clear display of temperatures and states of alarmsuniversal power supply AC/DC 24-270 VAccessory: Installation frame ER6 for panel mount ZIEHL devices neatly integrated into control panels and control cabinet doors with our installation frames type ER! More information here Discover the difference between our TR640IP, TR660IP and UR840IP! Type TR640IP TR660IP UR840IP Sensors PTC, Pt100, Pt1000 PTC, Pt100, Pt1000 Pt100, Pt1000, KTY83, KTY84, thermocouples, 0-10V, 0/4-20mA Sensor inputs 6 6 8 Digital inputs - - 4 Outputs 4x alarm relays 6x alarm relays, 2x analog (only T224370) 4x alarm relays, 1x analog Alarm types Limit value, differential, rate of change of temperature, 2 out of x Limit value, differential, rate of change of temperature, 2 out of x Sensor-specific limit values, differential, average, min/max, 2 out of x Virtual sensors - - 8 Display Display, LED Display, LED Display, LED Network / Communication Ethernet RS485 (only T224371), Ethernet RS485, Ethernet Other functions On/off delay, simulation, cyclic relay test, 2 digital inputs On/off delay, simulation, cyclic relay test, 2 digital inputs On/off delay, simulation, expansion with URB or STWA4MH Housing V6 V8 V8

Bild 1 Universal-Relais Typ UR840IP
Universal Relay Type UR840IP

Web-IO universal limit value relay with Ethernet interface, built-in web server and 8 inputs for temperature sensors or other analog signals. The UR840IP can be connected to the internet or an intranet and operated via TCP/IP from a normal PC with a suitable browser.The device can simultaneously evaluate and monitor up to 8 different input signals. Each of the 4 output relays can be assigned up to 8 limit values, one per input. If a limit value is reached, an alarm is triggered and a relay switches. Example: Alarm 1 is activated when a temperature is exceeded at sensor input 3 (e.g. Pt 100) or the signal from a pressure transmitter (e.g. 4-20 mA) at input 5 falls below a limit value. The device also has an RS485 interface (Modbus RTU) that can be used to connect current sensors type STWA4MH and the relay box type URB40.NEW: Data visualization in the web interface.Expandable by 4 additional relay outputs with the URB40! ZIEHL devices neatly integrated into control panels and control cabinet doors with our installation frames type ER! More information hereAccessory: Installation frame ER8 for panel mount ApplicationsThe UR840IP is used where one or more of the following features a required:The UR840IP is used to advantage wherever the following features are requiredmonitor up to 8 different analogue measured values and transfer them to the InternetMeasured value query and remote maintenance via intranet/internet Discover the difference between our UR series! Type UR420IP UR840IP Sensors PT100, PT1000, KTY83, KTY84, thermocouples, 0-10V, 0/4-20mA PT100, PT1000, KTY83, KTY84, thermocouples, 0-10V, 0/4-20mA Sensor inputs 4 8 Digital inputs 2 4 Outputs 2x alarm relays 4x alarm relays, 1x analog Alarm types Sensor-specific thresholds, difference, rate of change temperature, 2 out of X Sensor-specific thresholds, difference, rate of change temperature, 2 out of X Virtual sensors 4 8 Display Display, LED Display, LED Configuration Joystick, web interface Joystick, web interface Network / Communication RS485, Ethernet RS485, Ethernet Other functions On/off delay, simulation, expansion with URB or STWA4MH On/off delay, simulation, data visualization, expansion with URB or STWA4MH Housing V6 V8 Applications Measurement monitoring and control Measurement monitoring and control

All products

All products

Filter

Bild 1 TR250, Temperaturrelais Pt 100/1000, KTY, PTC, 3 Sensoren, 3 Alarme

Temperature-Relay Type TR250

The Pt100 thermostat TR250 monitors up to 3 sensors Pt100 (RTD), Pt1000, KTY83 KTY84 or thermistors (PTC) at the same time. Different types of sensors, e.g. Pt 100 and PTC can be monitored simultaneously.The unit is especially suitable for monitoring motors, generators and transformers.An other application is the use as a 2- or 3-step-controller with additional monitoring of over- or under-temperature. monitoring of differences in temperatures of 2 sensors  or  temperature controller for heat pumps.ZIEHL devices neatly integrated into control panels and control cabinet doors with our installation frames type ER! More information hereFunctionMeasuring an dmonitoring range -199...+850 °CResolution 0.1 °C for measuring range –19.9...99.9 selectable3 relay-outputs K1 to K3 with change-over-contactsUniversal power-supply AC/DC 24-240 VEasy settingStoring of values of MIN- and MAX temperatureAlarm counter for 3x99 alarms with display of sensor and elapsed timeCode-lock against manipulation of settingsReplacement for Elbag/Joppich TS-023 Sensor inputs: Pt 100 (RTD) or Pt 1000, 2- or 3-wire-connection, KTY83, KTY84Thermistors (PTC) each 1...6 in seriesMonitoring of short-circuit and breakDisplays:3 digit 7 segment display for temperature and programming3 LEDs for sensors, for alarms/relaysdisplay °C or °F selectable, resolution 0.1 °CSwitching functions:3 relayswarmest/coldest sensor switches relay3 LEDs for alarm/relayprogrammable for every relay:hysteresisautoreset or electronic reclosing lockdelay time for switching and switching backoperating- or closed current-modecyclic check of functionmonitoring of difference in temperature6 preset programs:Motor /generator 3x Pt 100transformer with 3x Pt 100transformer with 2x PTC and 1x Pt 100transformer with 2x PTC / 3x PTC3 x 1 alarm per sensorAccessory: Front mounting kit type ER4Alternative: Temperature relay Type TR640IP

Bild 1 Kaltleiter-Relais Typ MSR220K

PTC-Resistor-Relay Type MSR220K

ZIEHL PTC-resistor relays protect motors, transformers, machines and equipment against thermal overload. With ZIEHL PTC Sensors MINIKA ® applied they offer best solutions for nominal response temperatures 60°C…180°C.ZIEHL PTC-resistor relays are designed for PTC-sensors according to DIN 44081 and DIN 44082. Therefor sensor and relays are exchangeable. PTC-resistor sensors are suitable for the installation into windings of electrical machines, bearings and transformers as well as to monitor the temperature of liquid media, airflow and gases.Used in conjunction, they provide a effectively and reliable protection in case ofblocking rotors, heavy starts, countercurrent operationundervoltage and phase failureincreased ambient temperature and hindered coolingReplaces the following items:  MS220K: T221741, T221743, T221761, T221765 and T221749MSR220K: T221771 and T221775Functional overview1 PTC-resistor set with up to 6 PTC-sensors (250O), or bimetal contacts in seriesoutput relay with 1 or 2 change-over contact (co)operating status display with LEDK-Housing, vertical terminal orderwidth 22.7 mmsnap mounting on 35 mm standard DIN rail or screw mountingelectronic reclosing lock (disconnectable)integrated RESET-buttonlink for external RESETautomatic RESET at voltage recoveryLEDs for power ON (green) and ALARM (red) in reset-buttonUL recognized componentOption: other supply voltagesVersion with spring terminals RoHS/REACH compliantFurther information can be found in our customer information: “New terminals for K-type devices” 

Bild 1 Kaltleiter-Relais Typ MSF220K

PTC-Relay type MSF220K

PTC-relay for the monitoring of dry transformers. Alarm 1 with relay in closedcircuit current mode for preliminary warning, releases at over-temperature at PTC-set 1 and serves at the same time as functional monitoring. Alarm 2 in operating current mode. Thus no wiping signal occurs when switching on the supply voltage on. Additional terminals enable comfortable wiring from supply voltage to relays K1 and/or K2.Changes from T221717 / T221718 to T228143 / T228144: Version with spring terminals RoHS/REACH compliantFurther information can be found in our customer information: "New terminals for K-type devices"Changes from T221715 / T221716 to T221717 / T221718: cURus, monitoring of sensors for short circuit an interrupt activatable, improved test functionFunctions2 PTC resistor sets2 output relays 1 change-over contact (co)/ 1 normally open contact (no)monitoring of sensors for short-circuit and break activatableTEST-button (delayed)LEDs for ON, alarm 1 and 2red LEDs for alarm 1 and alarm 2K-type housingHousing for mounting on DIN-rail 35 mm or wall-mount with screws M4Replacement for foreign device Elbag/Joppich TS-01 

Bild 1 TR640IP, Temperaturrelais für Pt 100/1000, PTC 6 Sensoren, 4 Limits, TCP/IP

Temperature Relay Type TR640IP

Temperature Relays TR640IP monitor up to 6 sensors for up to 4 limits. Different sensors can be connected at the same time, e.g. Pt 100 (RTD) and PTC thermistors. Typical applications are monitoring of motors, generators or transformers. An other application is the use as a two or more step controller with additional monitoring of over- or undertemperature or monitoring of differences in temperatures of 2 sensors.Preset programs allow easy setting e.g. monitoring of transformers with/without monitoring of temperature of core or with/without controlling a ventilator.If evaluation "2 out of x" is activated with several connected sensors, an alarm is only triggered when the limit value is exceeded in 2 sensors. This prevents false alarms due to a fault in one sensor. Operation can be made at the device or with a standard browser via Ethernet.6 inputs for sensors Pt 100, Pt 1000 and PTC, mixed sensors possible4 alarms / relay outputsalarm 2 of x = alarm only when limit is exceeded in min. 2 sensorsmonitoring of difference of temperaturesmonitoring of rate of change of temperaturelogging of temperatures and historypreset programs for protection of motors, transformers and moreinterface ethernet TCP/IP, values available via modbus TCPprogramming with browser via TCP/IP or with joystick at devicecoloured LED display for clear display of temperatures and states of alarmsuniversal power supply AC/DC 24-270 VAccessory: Installation frame ER6 for panel mount ZIEHL devices neatly integrated into control panels and control cabinet doors with our installation frames type ER! More information here Discover the difference between our TR640IP, TR660IP and UR840IP! Type TR640IP TR660IP UR840IP Sensors PTC, Pt100, Pt1000 PTC, Pt100, Pt1000 Pt100, Pt1000, KTY83, KTY84, thermocouples, 0-10V, 0/4-20mA Sensor inputs 6 6 8 Digital inputs - - 4 Outputs 4x alarm relays 6x alarm relays, 2x analog (only T224370) 4x alarm relays, 1x analog Alarm types Limit value, differential, rate of change of temperature, 2 out of x Limit value, differential, rate of change of temperature, 2 out of x Sensor-specific limit values, differential, average, min/max, 2 out of x Virtual sensors - - 8 Display Display, LED Display, LED Display, LED Network / Communication Ethernet RS485 (only T224371), Ethernet RS485, Ethernet Other functions On/off delay, simulation, cyclic relay test, 2 digital inputs On/off delay, simulation, cyclic relay test, 2 digital inputs On/off delay, simulation, expansion with URB or STWA4MH Housing V6 V8 V8

Bild 1 Kaltleiter-Relais Typ MSF220SE

PTC-relays Type MSF220SE

The PTC-resistor trip device MSF220SE monitors the winding temperature of machines and equipment. Signals, that can be used as ”early warning" or ”malfunction" (switching-off), are transmitted as soon as the admissible limit temperature is exceeded.Two PTC-circuits can be connected to this unit. The integrated rise-delay time ensures a reliable mains voltage build-up.Function2 PTC resistor circuits, 1 to 6 PTC each (max. cold resistance of circuit 1500O each)potential-free contact for alarm 1potential-free contact for alarm 2voltage of pin 3 is connectet to pin 1 with a time delay of 2 sec., replacing an additional timing relay.alarm 3 for check of relay K3LED´s signal state of relays K1 and K2relay K3 picks up time-delayedTEST-button for ALARM 1 and ALARM 2NoteThanks to the delayed switching-on of the error message (approx. 2 s) after the switching-on, this device is especially suitable where an auxiliary voltage is not available and the secondary voltage of the monitored transformer is being used. The MSF220SE can furthermore be used advantageously when combining it with operating current releases. For additional devices, the control voltage is available at terminal 1 time-delayed. In case of a breakdown of the supply voltage, the control voltage is available at terminal 7 and can be used as a message. (Attention! This message will also be given for approx. 2 s. after switching-on.)Functional descriptionPTC-circuits in closed-circuit current principle. When the closed-circuit current flows, both output relays K1, K2 are picked up. Approx. 2 sec. after switching on supply power, relay K3 picks up time-delayed, closing the contact circuits at terminals 31, 14 and 31, 24. As soon as the temperature of the early warning has been reached, relay K1 releases (terminal 31, 12 closed), the alarm 1 is given. If the temperature of malfunction is reached, also relay K2 releases (terminal 31, 22 closed). This alarm 2 can be used to switch off the equipment. If the temperature drops to approx. 5 °C below the temperature of malfunction or early warning, the relays K1 and K2 resp. are switched on again.TEST: LED "ON" – flash -> +2 s -> Alarm 1 -> +3 s -> Alarm 2 

Bild 1 Trafoschutz-Temperaturrelais TR440

Transformer Protection Temperature Relay Type TR440

Temperature relay to protect transformers against excess temperature and to control a fan.The temperatures in the windings are monitored with three Pt 100 sensors. The core temperature can be monitored with a fourth sensor.The 4 alarms/output relays are used to control the fan, to signal an advance warning and to switch-off the transformer. Various programs facilitate using the alarm ideally for each application. Depending on the program, e.g. an extra relay is available for the fault message or for triggering due to exceeding the maximum core temperature.Other usesAlternatively, with the fourth sensor the temperature of the room the transformer is located in can be monitored and, with the alarm, the room ventilation can be controlled. The device can also be used for other tasks for temperature monitoringe.g., for motors.Overview of the functions4 Sensor inputs Pt 100 (RTD), 2 or 3-wire connectionLarge monitoring range -199…+850°C / -199...+999°F4 Alarms / Relays3-digit digital display (resolution 1°C / 1°F)4 LEDs sensor4 LEDs relay4 LEDs alarm1 LED errorControl voltage AC/DC 24-240 VClear displays and simple programmingMin and max sensor values can be savedCode lock against unintended / unauthorised changes to the settingsOptional RS 485 interface with Modbus RTU protocolEasySimulation for simple sensor value simulation 

Bild 1 MSF220VU, Kaltleiter-Relais für Trockentrafos Fan - Vorwarnung - Abschaltung, AC/DC 24-240 V

PTC-Resistor Relay MSF220VU

The MSF220VU is particularly suitable for the temperature monitoring at dry transformers. 3 PTC-circuits with different nominal response temperatures (NRT) can be connected to this unit, one for controlling a fan (forced cooling) and two for alarms. Each PTC-circuit is monitored for break and short circuit. This reduces the probability of false alarms.3 PTC-circuitsUniversal supply voltage AC/DC 24-240 Vintelligent control of fan (relay K0, 1 normally-open contact)ALARM 1 in closed-circuit current mode (relay K1, 1 change-over contact) for pre alarm. Signals also error in any sensor and interruption of supply voltage. ALARM 2 in operation current mode (relay K2, 1 changeover contact). No signal when switching on and off the supply voltage.all output relays potentially separated from each other.monitoring of sensor linesTEST-button (stop possible before ALARM 2)Simple testing with disconnectable monitoring of break and short circuit  (for 10 minutes).LEDs for ON, sensor error, Fan, ALARM 1 and ALARM 2UL recognized componentplug-in terminalshousing for mounting on DIN-rail or wall-mountmounting height 55 mmAccessory: Installation Frame ER4 for panel mount

Bild 1 Universal-Relais Typ UR840IP

Universal Relay Type UR840IP

Web-IO universal limit value relay with Ethernet interface, built-in web server and 8 inputs for temperature sensors or other analog signals. The UR840IP can be connected to the internet or an intranet and operated via TCP/IP from a normal PC with a suitable browser.The device can simultaneously evaluate and monitor up to 8 different input signals. Each of the 4 output relays can be assigned up to 8 limit values, one per input. If a limit value is reached, an alarm is triggered and a relay switches. Example: Alarm 1 is activated when a temperature is exceeded at sensor input 3 (e.g. Pt 100) or the signal from a pressure transmitter (e.g. 4-20 mA) at input 5 falls below a limit value. The device also has an RS485 interface (Modbus RTU) that can be used to connect current sensors type STWA4MH and the relay box type URB40.NEW: Data visualization in the web interface.Expandable by 4 additional relay outputs with the URB40! ZIEHL devices neatly integrated into control panels and control cabinet doors with our installation frames type ER! More information hereAccessory: Installation frame ER8 for panel mount ApplicationsThe UR840IP is used where one or more of the following features a required:The UR840IP is used to advantage wherever the following features are requiredmonitor up to 8 different analogue measured values and transfer them to the InternetMeasured value query and remote maintenance via intranet/internet Discover the difference between our UR series! Type UR420IP UR840IP Sensors PT100, PT1000, KTY83, KTY84, thermocouples, 0-10V, 0/4-20mA PT100, PT1000, KTY83, KTY84, thermocouples, 0-10V, 0/4-20mA Sensor inputs 4 8 Digital inputs 2 4 Outputs 2x alarm relays 4x alarm relays, 1x analog Alarm types Sensor-specific thresholds, difference, rate of change temperature, 2 out of X Sensor-specific thresholds, difference, rate of change temperature, 2 out of X Virtual sensors 4 8 Display Display, LED Display, LED Configuration Joystick, web interface Joystick, web interface Network / Communication RS485, Ethernet RS485, Ethernet Other functions On/off delay, simulation, expansion with URB or STWA4MH On/off delay, simulation, data visualization, expansion with URB or STWA4MH Housing V6 V8 Applications Measurement monitoring and control Measurement monitoring and control

Bild 1 Kaltleiter-Relais Typ MSF220VL

PTC-relays Type MSF220VL

The MSF220VL is particularly suitable for monitoring of temperatures at dry transformers, when also the temperature of the core shall be measured. Monitoring of core temperature is especially required in rectifier transformers because of harmonics causing heat in the core.An intelligent control prolongs automatically the runtime of a cooling-fan, depending on the load of the transformer. Each PTC-circuit is monitored for break and short circuit. This reduces probability of false alarms. Relays in operating-current mode prevent from a trip-signal when switching on supply voltage.The device can be adapted to different applications with 4 programs:Fan-control - alarm - trip (winding) - trip (core)Alarm - trip (winding) - trip (core) - alarm (fault)Fan-control - alarm - trip (winding) - alarm (fault)Fan-control with hysteresis T1/T2 - alarm – trip (winding) - time relayOverview of functions4 inputs for PTCIntelligent control of fanAutomatic fan-test 1x / weekelectronic reclosing lock for alarms (trip) connectableMonitoring of sensorsTest-buttonSimple testing with disconnectable monitoring of break and short circuit (for 10 minutes)cURusLEDs for alarms, states of relays and sensorsHousing for mounting on DIN-Rail or wall-mount(option)Mounting height 55 mmUniversal supply voltage AC/DC 24-240 VDEWA-standard for DubaiAccessory: Front mounting kit type ER4

Bild 1 TR400, Digitaldisplay -199...800 °C Pt 100-Temperaturrelais

Pt 100-Temperature Relay Type TR400

Attention: Discontinued model - remaining stock available. We recommend the following devices as alternatives: CharacteristicsTR640IPTR660IPSensorsPTC, PT100, PT1000PTC, PT100, PT1000Number of sensor inputs66Outputs4x alarm relay6x alarm relay, 2x analog (only T224370)Alarm typeThreshold value, difference, rate of change, 2 out of XThreshold value, difference, rate of change, 2 out of XDisplayDisplay, LEDDisplay, LEDParameterizationJoystick, web interfaceJoystick, web interfaceNetwork / CommunicationEthernetRS485, EthernetOther functionsSwitch-on and switch-off delay, simulation, cyclic relay test, 2 digital inputsSwitch-on and switch-off delay, simulation, cyclic relay test, 2 digital inputsHousing designV6V8Main areas of applicationExtended monitoring for motors, Transformers, differential monitoringAdditional alarms, analog outputs, versatile application in all industrial sectors Description TR400:The Pt 100 thermostat TR400 is a temperature controller and monitors up to 4 Pt 100 sensors at the same time. 4 switching points and 4 relays permit almost any combination of switching action. It also can select the highest temperature of a group of2,  3 or 4 sensors. The temperatures of two sensors or groups of sensors can be issued to 2 analog outputs i.e. for remote displays or further evaluation. Programming is very variable and simple.Due to the fact that 4 type Pt 100 sensors can be connected, the unit is especially suitable for temperature monitoring wherever up to 4 different measuring points must be monitored simultaneously:motors and generators with simultaneous monitoring of bearings and coolant.transformers with additional monitoring of the core temperature also.power machines and plantsOverview of functionsMeasuring and monitoring range -199 ... +800 °C4 sensor inputs with 2- or 3-wire connection4 relay outputs K1 to K4 with change-over contactSensor Error Relay K7 monitors sensor break or sensor short circuit as well as aninterruption of the power-supply.2 analog outputs, 0/4...20 mA und 0/2...10 V, with individual scaling.Universal power supply AC/DC 24-240 VTerminal for USB-Stick for up- and downloads of sets of parameters and for firmware- updatesAccessory: Installation frame ER8 for panel mountAlternative: Temperature Relay Type TR660IP

Bild 1 TR660IP, Temperaturrelais für Pt 100, PT1000, PTC 6 Sensoren, 7 Limits, TCP/IP

Temperature Relay Type TR660IP

Temperature Relays TR660IP monitor up to 6 sensors for up to 7 limits. Different sensors can be connected at the same time, e.g. Pt 100 (RTD) and PTC thermistors. Typical applications are monitoring of motors, generators or transformers. An other application is the use as a two or more step controller with additional monitoring of over- or undertemperature or monitoring of differences in temperatures of 2 sensors.Preset programs allow easy setting e.g. monitoring of transformers with/without monitoring of temperature of core or with/without controlling a ventilator.If the evaluation "2 out of x" is activated with several connected sensors, an alarm is only triggered when the limit value is exceeded in 2 sensors. This prevents false alarms due to a fault in one sensor. Operation can be made at the device or with a standard browser via Ethernet.6 inputs for sensors Pt 100, Pt 1000 and PTC, mixed sensors possible7 alarms / relay outputsalarm 2 of x = alarm only when limit is exceeded in min. 2 sensorsmonitoring of difference of temperaturesmonitoring of rate of change of temperaturelogging of temperatures and historypreset programs for protection of motors, transformers and moreinterface ethernet TCP/IP, values available via modbus TCPprogramming with browser via TCP/IP or with joystick at devicecoloured LED display for clear display of temperatures and states of alarmsuniversal power supply AC/DC 24-270 VAccessory: Installation frame ER8 for panel mount ZIEHL devices neatly integrated into control panels and control cabinet doors with our installation frames type ER! More information here TR660IP RS485:  interface RS485 (modbus RTU)TR660IP analog:  4 analog outputs 2x 0/4 - 20 mA and 2x 0/2 - 10 V, isolated from sensor inputs, individually programmable.  Discover the difference between our TR640IP, TR660IP and UR840IP! Type TR640IP TR660IP UR840IP Sensors PTC, Pt100, Pt1000 PTC, Pt100, Pt1000 Pt100, Pt1000, KTY83, KTY84, thermocouples, 0-10V, 0/4-20mA Sensor inputs 6 6 8 Digital inputs - - 4 Outputs 4x alarm relays 6x alarm relays, 2x analog (only T224370) 4x alarm relays, 1x analog Alarm types Limit value, differential, rate of change of temperature, 2 out of x Limit value, differential, rate of change of temperature, 2 out of x Sensor-specific limit values, differential, average, min/max, 2 out of x Virtual sensors - - 8 Display Display, LED Display, LED Display, LED Network / Communication Ethernet RS485 (only T224371), Ethernet RS485, Ethernet Other functions On/off delay, simulation, cyclic relay test, 2 digital inputs On/off delay, simulation, cyclic relay test, 2 digital inputs On/off delay, simulation, expansion with URB or STWA4MH Housing V6 V8 V8

Bild 1 Pt 100-Temperaturrelais Typ TR1200IP

Pt 100-Temperature relays Type TR1200IP

Temperature-relays TR1200IP measure the temperature of up to 12 sensors within 199...+850 °C and provide the data at an ethernet interface for external evaluation. With its universal power-supply AC/DC 24-240 V it can be connected to all common supply-voltages. Actual measured values and stored min- and max-values can be displayed in a normal browser.At the ethernet interface the following protocols are available:Modbus TCPZIEHL RTDIEC61850 (GOOSE) ATTENTION: for part-no. T224078 onlyThe TR1200IP itself does not monitor temperatures for limits. For direct monitoring of temperatures our devices with alarms and output relays are recommended.It is used where temperatures of many sensors Pt100 shall be measured and transmitted via ethernet.Applications are e.g. monitoring of:Motors and generators (windings, bearings, coolant, ambient temperature)Transformers (windings, core, ambient temperature)Maschines, plants and equipmentSensors and displays:12 inputs for sensors Pt 100 (RTD)Connection in 2- or 3-wireunneeded inputs can be switched offMonitoring of sensors for short-circuit an interrupt3-digit-display for temperatureLEDs for assigning the measured value, error, state of relay and interfaceInterface:10 MBit/s Ethernetsupports IEC 61850 GOOSEProtocol ZIEHL-standard RTD or Modbus TCPProtocol details see www.ziehl.de - operating manuals

Bild 1 PTC-Simulator

PTC-Simulator

Normal PTC-resistor relays can be tested by simply disconnecting the sensor. PTC-resistor relays with monitoring of sensor short-circuit and break need more sophisticated test-equipment.With help of the ZIEHL MS-Tester also these relays can be easily tested for correct function. The included cable is designed for the connection of relays type MSF 220 V(U). Also any other PTC-resistor relay can be connected to the MS-Tester.Testdisconnect the PTC-resistor relayconnect the MS-Tester (T/0, T/1 and/or T/3) to the sensor inputsswitch on the relayincrease the resistance with the potentiometer (turn slowly) until the appropriate Alarm switchesreduce the resistance until the relay switches back (or a LED signals, that it is ready to switch back)if necessary, the values of the switching points can be measured at the terminals T/0, T/1, T/2 after disconnecting the relay. Typical values are 3000 O ... 4000 O for tripping and >1500 O for switching back.test break with push-button (only at relays with monitoring of sensor/line-break)test short circuit with push-button (only at relays with monitoring of sensor/lineshort-circuit)ATTENTION: At relay MSF 220 V(U), break or short-circuit in any sensor will result in an error message = ALARM 1. The LED "sensor" lights and the LED of the appropriate alarm blinks.HINT: cold PTCs have a resistance of 20...250 O, typical 50...120 O per sensor.

Bild 1 Trafoschutzrelais Trafosafe TS1000

Trafoschutzrelais Trafosafe Type TS1000

The Trafosafe TS1000 is applied at transformers with forced cooling. It monitors the temperature of the transformer with 3 sensor-circuits (PTC-thermistors), controls the forced cooling depending on the load of the transformer, reports exceeding of alarm-temperature and switches off the transformer (trip) when increasing of the temperature continues.Up to 6 fans can be controlled and monitored directly with the TS1000. Contactors and motor protection switches are not necessary any more.At Pt 100-monitored transformers the TS1000 can be used to control only the fans.Temperature-Monitoring1 PTC-circuit for controlling the cooling (1T1/1T2) = input for starting fan when using as fan-control only2 x 1 PTC-circuit for alarm 1 (2T1/2T2) and alarm 2/trip (3T1/3T2), monitored for short-circuit and interruptionAlarm1 (K2) in closed-circuit current mode = monitoring of functionAlarm 2/trip (K3) in open-circuit current mode = no signal/tripping when switching on the deviceTest-/Reset-button for testing the functionFan-Control and Monitoring of fandirect connection of up to 6 fans 0.07...4.0 Aautomatic exceeding of the on-time of the fans at high load of the transformerMonitoring of failure fan (over-/undercurrent)Self-calibration of the monitored values of the currents to the fansSwitching-point for current-failure adjustable ± 5-40%automatic test of fans 1-30 days, disconnectableRelay for reporting fan-failureClear displays with LEDsGeneralUniversal Power Supply AC/DC 24-240 Vcompact housing for cabinet-mount, 140 mm wide, mounting heigt 55 mmAttachment on 35 mm standard rail or with 3 screws M4

Bild 1 TR600, Temperaturrelais für Pt 100, 6 Sensoren, 6 Alarme, RS 485 (Modbus RTU)

Pt 100-Temperature relay Type TR600

Attention: Discontinued model - remaining stock available.Version T224360 with analog output no longer available. We recommend the following devices as alternatives: Characteristics TR640IP TR660IP Sensors PTC, PT100, PT1000 PTC, PT100, PT1000 Number of sensor inputs 6 6 Outputs 4x alarm relay 6x alarm relay, 2x analog (only T224370) Alarm type Threshold value, difference, rate of change, 2 out of X Threshold value, difference, rate of change, 2 out of X Display Display, LED Display, LED Parameterization Joystick, web interface Joystick, web interface Network / Communication Ethernet RS485, Ethernet Other functions Switch-on and switch-off delay, simulation, cyclic relay test, 2 digital inputs Switch-on and switch-off delay, simulation, cyclic relay test, 2 digital inputs Housing design V6 V8 Main areas of application Extended monitoring for motors, Transformers, differential monitoring Additional alarms, analog outputs, versatile application in all industrial sectors Description TR600:The Pt 100 thermostat TR600 is a temperature controller and monitors up to six Pt 100 sensors at the same time. Six switching points and six relays allow almost any combination of switching action. It can also select the highest temperature of a group of three or six sensors. The temperatures of two sensors or groups of sensors can be issued to two analog outputs i.e. for remote displays or further evaluation. Programming is very variable and simple.Due to the fact that 6 type Pt 100 sensors can be connected, the unit is especially suitable for temperature monitoring wherever up to 6 different measuring points must be monitored simultaneously:motors and generators with simultaneous monitoring of bearings and coolant.transformers with additional monitoring of the core temperature also.power machines and plantsApprovalUL E377414 Process Control Equipment, Electrical - ComponentOverview of functionsMeasuring and monitoring range -199 ... +800 °C6 sensor inputs with 2- or 3-wire connection7 relay outputs with change-over contactAlarm 1 … 6 relay K1 (11/12/14) ... K6 (61/62/64)Sensor Error Relay K7 (71/72/74) monitors sensor break or sensor short circuit.2 analog outputs, 0/4...20 mA and 0/2...10 V, with individual scaling.Universal power supply. 2 ranges AC/DC 24-60V or AC/DC 90-240 VUniversal power supply AC/DC 24-240 VTerminal for USB-Stick for up- and downloads of sets of parameters and for firmware-updatesAccessory: Installation frame ER8 for panel mount 

How may I assist you?
ProxaChatbaseAI.questions.logo

Zetty

Digital Assistant

ProxaChatbaseAI.questions.logo

Welcome to ZIEHL industrie-elektronik GmbH + Co KG! I am Zetty, your digital assistant. Since many of my answers are generated by artificial intelligence, please double-check important information to make sure everything is correct.

Content partly AI-generated. Before using our products, it is necessary by qualified personnel is required. No liability for incorrect information. Learn more
ProxaChatbaseAI.questions.logo