Skip to main content Skip to search Skip to main navigation
Go to homepage
Skip product gallery

New products

Bild 1 TR660IP, Temperaturrelais für Pt 100, PT1000, PTC 6 Sensoren, 7 Limits, TCP/IP
Temperature Relay Type TR660IP

Temperature Relays TR660IP monitor up to 6 sensors for up to 7 limits. Different sensors can be connected at the same time, e.g. Pt 100 (RTD) and PTC thermistors. Typical applications are monitoring of motors, generators or transformers. An other application is the use as a two or more step controller with additional monitoring of over- or undertemperature or monitoring of differences in temperatures of 2 sensors.Preset programs allow easy setting e.g. monitoring of transformers with/without monitoring of temperature of core or with/without controlling a ventilator.If the evaluation "2 out of x" is activated with several connected sensors, an alarm is only triggered when the limit value is exceeded in 2 sensors. This prevents false alarms due to a fault in one sensor. Operation can be made at the device or with a standard browser via Ethernet.6 inputs for sensors Pt 100, Pt 1000 and PTC, mixed sensors possible7 alarms / relay outputsalarm 2 of x = alarm only when limit is exceeded in min. 2 sensorsmonitoring of difference of temperaturesmonitoring of rate of change of temperaturelogging of temperatures and historypreset programs for protection of motors, transformers and moreinterface ethernet TCP/IP, values available via modbus TCPprogramming with browser via TCP/IP or with joystick at devicecoloured LED display for clear display of temperatures and states of alarmsuniversal power supply AC/DC 24-270 VAccessory: Installation frame ER8 for panel mountTR660IP RS485:  interface RS485 (modbus RTU)TR660IP analog:  4 analog outputs 2x 0/4 - 20 mA and 2x 0/2 - 10 V, isolated from sensor inputs, individually programmable. 

Bild 1 TR640IP, Temperaturrelais für Pt 100/1000, PTC 6 Sensoren, 4 Limits, TCP/IP
Temperature Relay Type TR640IP

Temperature Relays TR640IP monitor up to 6 sensors for up to 4 limits. Different sensors can be connected at the same time, e.g. Pt 100 (RTD) and PTC thermistors. Typical applications are monitoring of motors, generators or transformers. An other application is the use as a two or more step controller with additional monitoring of over- or undertemperature or monitoring of differences in temperatures of 2 sensors.Preset programs allow easy setting e.g. monitoring of transformers with/without monitoring of temperature of core or with/without controlling a ventilator.If evaluation "2 out of x" is activated with several connected sensors, an alarm is only triggered when the limit value is exceeded in 2 sensors. This prevents false alarms due to a fault in one sensor. Operation can be made at the device or with a standard browser via Ethernet.6 inputs for sensors Pt 100, Pt 1000 and PTC, mixed sensors possible4 alarms / relay outputsalarm 2 of x = alarm only when limit is exceeded in min. 2 sensorsmonitoring of difference of temperaturesmonitoring of rate of change of temperaturelogging of temperatures and historypreset programs for protection of motors, transformers and moreinterface ethernet TCP/IP, values available via modbus TCPprogramming with browser via TCP/IP or with joystick at devicecoloured LED display for clear display of temperatures and states of alarmsuniversal power supply AC/DC 24-270 VAccessory: Installation frame ER6 for panel mount ZIEHL devices neatly integrated into control panels and control cabinet doors with our installation frames type ER! More information here Discover the difference between our TR640IP, TR660IP and UR840IP! Type TR640IP TR660IP UR840IP Sensors PTC, Pt100, Pt1000 PTC, Pt100, Pt1000 Pt100, Pt1000, KTY83, KTY84, thermocouples, 0-10V, 0/4-20mA Sensor inputs 6 6 8 Digital inputs - - 4 Outputs 4x alarm relays 6x alarm relays, 2x analog (only T224370) 4x alarm relays, 1x analog Alarm types Limit value, differential, rate of change of temperature, 2 out of x Limit value, differential, rate of change of temperature, 2 out of x Sensor-specific limit values, differential, average, min/max, 2 out of x Virtual sensors - - 8 Display Display, LED Display, LED Display, LED Network / Communication Ethernet RS485 (only T224371), Ethernet RS485, Ethernet Other functions On/off delay, simulation, cyclic relay test, 2 digital inputs On/off delay, simulation, cyclic relay test, 2 digital inputs On/off delay, simulation, expansion with URB or STWA4MH Housing V6 V8 V8

Tip
Bild 1 AC-Elektronik-Stromwandler Typ STWA4MH
Electronic Current-Transducer Type STWA4MH

STWA4MH is a measuring transducer. It measures AC up to 60A and has an RS485 interface (Modbus RTU). The measured analog current value is made available as a digital signal and can be read by a PLC, an IPC or a master computer.The conductor to be measured is passed through an opening (Ø 11 mm). In case of small currents, the sensitivity of the current transducer can be increased by looping through the current-carrying conductor several times, e.g. double looping doubles the sensitivity. The measuring range of the STWA4MH is reduced by multiple looping. To measure currents of any size, the STWA4MH is simply looped into the secondary circuit of a large current transformer with a secondary output of 5A (lead the cable through STWA4MH several times).Application:The STWA4MH enables the space-saving an cost-effective measurement of the actual value of an alternating current. Compared to transducers with analog output, the bus technology significantly  reduces the effort for the hardware (inputs) and the wiring. Applications are e.g. the recording of the current consumption of electrical motors in processing machines. Here the feed can be regulated depending on the load on the motor. Another example is the monitoring of consumers, e.g. heating elements, for failure.

All products

All products

Filter

Tip
Bild 1 AC-Elektronik-Stromwandler Typ STWA4MH

Electronic Current-Transducer Type STWA4MH

STWA4MH is a measuring transducer. It measures AC up to 60A and has an RS485 interface (Modbus RTU). The measured analog current value is made available as a digital signal and can be read by a PLC, an IPC or a master computer.The conductor to be measured is passed through an opening (Ø 11 mm). In case of small currents, the sensitivity of the current transducer can be increased by looping through the current-carrying conductor several times, e.g. double looping doubles the sensitivity. The measuring range of the STWA4MH is reduced by multiple looping. To measure currents of any size, the STWA4MH is simply looped into the secondary circuit of a large current transformer with a secondary output of 5A (lead the cable through STWA4MH several times).Application:The STWA4MH enables the space-saving an cost-effective measurement of the actual value of an alternating current. Compared to transducers with analog output, the bus technology significantly  reduces the effort for the hardware (inputs) and the wiring. Applications are e.g. the recording of the current consumption of electrical motors in processing machines. Here the feed can be regulated depending on the load on the motor. Another example is the monitoring of consumers, e.g. heating elements, for failure.

Bild 1 Kaltleiter-Relais Typ MSR220K

PTC-Resistor-Relay Type MSR220K

ZIEHL PTC-resistor relays protect motors, transformers, machines and equipment against thermal overload. With ZIEHL PTC Sensors MINIKA ® applied they offer best solutions for nominal response temperatures 60°C…180°C.ZIEHL PTC-resistor relays are designed for PTC-sensors according to DIN 44081 and DIN 44082. Therefor sensor and relays are exchangeable. PTC-resistor sensors are suitable for the installation into windings of electrical machines, bearings and transformers as well as to monitor the temperature of liquid media, airflow and gases.Used in conjunction, they provide a effectively and reliable protection in case ofblocking rotors, heavy starts, countercurrent operationundervoltage and phase failureincreased ambient temperature and hindered coolingReplaces the following items:  MS220K: T221741, T221743, T221761, T221765 and T221749MSR220K: T221771 and T221775Functional overview1 PTC-resistor set with up to 6 PTC-sensors (250O), or bimetal contacts in seriesoutput relay with 1 or 2 change-over contact (co)operating status display with LEDK-Housing, vertical terminal orderwidth 22.7 mmsnap mounting on 35 mm standard DIN rail or screw mountingelectronic reclosing lock (disconnectable)integrated RESET-buttonlink for external RESETautomatic RESET at voltage recoveryLEDs for power ON (green) and ALARM (red) in reset-buttonUL recognized componentOption: other supply voltagesVersion with spring terminals RoHS/REACH compliantFurther information can be found in our customer information: “New terminals for K-type devices” 

Bild 1 Kaltleiter-Relais Typ MS220C

PTC-Resistor Relay Type MS220C

This compact device is the smallest version of all our PTCresistor relays.terminals outsideprotection terminals IP 20Relays 1 change-over-contact (co)Replacement for foreign device Zeidler TÜS 100  Type MS220C MS220K MSF220K MSR220K Art.-No. T221830 T221821 T221804 T221805 T228102 T228143 T228111 Number of Sensor Inputs 1xPTC 1xPTC 1xPTC 1xPTC 1xPTC 2xPTC 1xPTC Outputs 1x Changeover 1x Changeover 1x Changeover 1x Changeover 1xChangeover 1x Changeover, 1xCloser 1x 2 Changeover Alarm type Limit value; Fixed Limit value; Fixed Limit value; Fixed Limit value; Fixed Limit value; Fixed Limit value; Fixed Limit value; Fixed Alarm locked Short Circuit Monitoring PTC Line Break Monitoring PTC Display - - - - 1x Power LED, 1x Alarm LED 1x Power LED, 2x Alarm LED 1xAlarm, 1xPower Supply Voltage 24V AC/DC 24-240V AC/DC 220 - 240V AC 400V AC/DC 24-240V AC/DC 24 - 240V AC/DC 24-240V AC/DC Approvals CE, cuRUs, UKCA CE, cuRUs, UKCA CE, cuRUs, UKCA CE, UKCA CE, cuRUs, UKCA CE, cuRUs, UKCA CE, cuRUs, UKCA Housing design C C C C K K K

Bild 1 Kaltleiter-Relais Typ MSR220KA

PTC-Thermistor-Relay Type MSR220KA

PTC-relay for the application as a protection device against inadmissible heating up at electrical equipment in areas with explosive gases (zones 1 and 2) and areas with combustible dust (21 and 22), e.g. for direct temperature-monitoring of explosion-proof motors Ex e and Ex d. Vertically arranged terminals. Each terminal remains accessible even if all others are already occupied.Changes from T222471 to T228130: Version with spring terminals RoHS/REACH compliantChanges from T222476 to T228138: Version with spring terminals RoHS/REACH compliantChanges from T222475 to T228134: Version with spring terminals RoHS/REACH compliantChanges from T222473 to T228133: Version with spring terminals RoHS/REACH compliantFurther information can be found in our customer information: "New terminals for K-type devices"FeaturesATEX approval according to directive 2014/34/EUSIL 1 according to IEC 61508PL c according to ISO 138491 PTC-resistor (thermistor) set, for 1, 3 or 6 PTC-sensorsshort-circuit monitoring of sensor-circuitoutput-relay with 1 or 2 change-over contacts (co)electronic reclosing lock (disconnectable)integrated RESET-buttonlink for external resetautomatic reset at voltage recoveryRESET-Button with integrated LEDs for power-ON (green) and ALARM (red)K-housing, vertically arranged terminals housing 22.5 mm wideassembly on DIN-rail or with 2 screws M4 (option)UL Recognized ComponentOption: other supply voltages 

Bild 1 Phasenasymmetrierelais Typ PS2DK

Phase-Asymmetry Relay Type PS2DK

Phase asymmetry relays PS2DK are used for the protection of electric motors against asymmetries in the 3-phase mains without neutral and for monitoring the phase-sequence.The switching-point is adjustable and can be adapted to the situation in the mains. If a motor, running with 2 phases, creates the 3rd phase, the sensitivity can be increased. With mains with high harmonics it can be necessary to reduce the sensitivity.When the sensitivity is reduced to minimum (25% = potentiometer turned fully right) , the device works as a phase-sequence relay. It trips only at wrong phasesequence or missing phase.If there is a wrong phase-sequence when switching on the device, the relay does not pick up.Monitoring of phase-asymmetryMonitoring of phase-sequenceAdjustable sensitivity 5…25 %Output-relay with 2 change-over contactsSwitching delay adjustable 0,1 … 5 sLED for display state of operationChanges from P222505 to P227105: Version with spring terminals RoHS/REACH compliantFurther information can be found in our customer information: "New terminals for K-type devices"

Bild 1 Kaltleiter-Relais Typ MS220KA

PTC-Thermistor-Relay Type MS220KA

PTC-relay for the application as a protection device against inadmissible heating up at electrical equipment in areas with explosive gases (zones 1 and 2) and areas with combustible dust (21 and 22), e.g. for direct temperature-monitoring of explosion-proof motors Ex e and Ex d. Vertically arranged terminals. Each terminal remains accessible even if all others are already occupied.Changes from T222451 to T228114; T222455 -> T228115; T222445 to T228116: Version with spring terminals RoHS/REACH compliantFurther information can be found in our customer information: "New terminals for K-type devices"FeaturesATEX directive 2014/34/EUSIL 1 according to IEC 61508PL c according to ISO 138491 PTC-resistor (thermistor) set, for 1, 3 or 6 PTC-sensorsshort-circuit monitoring of sensor-circuitoutput-relay with 1 or 2 change-over contacts (co)2 LEDs for ON and ALARMK-housing, vertically arranged terminals housing 22.5 mm wideassembly on DIN-rail or with 2 screws M4 (option)UL Recognized ComponentOption: other supply voltages 

Bild 1 TR640IP, Temperaturrelais für Pt 100/1000, PTC 6 Sensoren, 4 Limits, TCP/IP

Temperature Relay Type TR640IP

Temperature Relays TR640IP monitor up to 6 sensors for up to 4 limits. Different sensors can be connected at the same time, e.g. Pt 100 (RTD) and PTC thermistors. Typical applications are monitoring of motors, generators or transformers. An other application is the use as a two or more step controller with additional monitoring of over- or undertemperature or monitoring of differences in temperatures of 2 sensors.Preset programs allow easy setting e.g. monitoring of transformers with/without monitoring of temperature of core or with/without controlling a ventilator.If evaluation "2 out of x" is activated with several connected sensors, an alarm is only triggered when the limit value is exceeded in 2 sensors. This prevents false alarms due to a fault in one sensor. Operation can be made at the device or with a standard browser via Ethernet.6 inputs for sensors Pt 100, Pt 1000 and PTC, mixed sensors possible4 alarms / relay outputsalarm 2 of x = alarm only when limit is exceeded in min. 2 sensorsmonitoring of difference of temperaturesmonitoring of rate of change of temperaturelogging of temperatures and historypreset programs for protection of motors, transformers and moreinterface ethernet TCP/IP, values available via modbus TCPprogramming with browser via TCP/IP or with joystick at devicecoloured LED display for clear display of temperatures and states of alarmsuniversal power supply AC/DC 24-270 VAccessory: Installation frame ER6 for panel mount ZIEHL devices neatly integrated into control panels and control cabinet doors with our installation frames type ER! More information here Discover the difference between our TR640IP, TR660IP and UR840IP! Type TR640IP TR660IP UR840IP Sensors PTC, Pt100, Pt1000 PTC, Pt100, Pt1000 Pt100, Pt1000, KTY83, KTY84, thermocouples, 0-10V, 0/4-20mA Sensor inputs 6 6 8 Digital inputs - - 4 Outputs 4x alarm relays 6x alarm relays, 2x analog (only T224370) 4x alarm relays, 1x analog Alarm types Limit value, differential, rate of change of temperature, 2 out of x Limit value, differential, rate of change of temperature, 2 out of x Sensor-specific limit values, differential, average, min/max, 2 out of x Virtual sensors - - 8 Display Display, LED Display, LED Display, LED Network / Communication Ethernet RS485 (only T224371), Ethernet RS485, Ethernet Other functions On/off delay, simulation, cyclic relay test, 2 digital inputs On/off delay, simulation, cyclic relay test, 2 digital inputs On/off delay, simulation, expansion with URB or STWA4MH Housing V6 V8 V8

Bild 1 Kaltleiter-Relais Typ MSR220VA

PTC-Thermistor-Relay Type MSR220VA

Ziehl PTC thermistor relays protect motors, transformers, machines and equipment against thermal overload. These are according to DIN EN 60947-8 and are thus exchangeable. Used in conjunction with respective PTC thermistors they provide a reliable temperature protection in the temperature range 60 °C up to 180 °C. The device is conform to EN IEC 60947-8. Thermistors according to DIN VDE V 0898-1-401 (ATEX) or equivalent detail specification (UKEX) shall be connected. PTC thermistors are suitable for the installation into windings of electrical machines, bearings and transformers as well as to monitor the temperature of liquid media, airflow and gases. With ATEX approval, explosion-protected equipment in explosive gas atmospheres (marking G: gas) or in areas with combustible dust (marking D: dust) can be protected.FeaturesATEX directive 2014/34/EU1 circuit for 1, 3 or 6 PTC thermistorsShort-circuit detection within the thermistor circuitOutput relay with 1 change-over contact (co)Operating status display with LEDelectronic reclosing lock (disconnectable)integrated RESET-buttonlink for external RESETautomatic RESET at voltage recoveryOperating status display with LED 

Bild 1 Drehrichtungsrelais Typ DRR10

Phase-Sequence Relay Type DRR10

Phase-sequence relays DRR10 measure the sequence of the phases when being switched on and switch - if necessary - the rotation of the field by changing 2 phases.The integrated PTC-monitor protects the motor from overheating.Applications are especially machines and equipment, that is operated at variable locations e.g. at building sites. Pumps, compressors and vacuum cleaners always run correctly. Nomore search for faults or change of wiring necessary.Overview of Functionautomatic change of wrong phase-sequence when connected falselyrunning backward of motors is avoidedintegrated PTC-protection for motorenable-input for direct switching on/off of the motor with DRR 10max. 3 x 12 Aswitch-on currents 30 A / max. 4 s / 60 A / max. 1 shigher currents with external contactorsintegrated protection for relay contactsintegrated protection from over-temperaturehousing for mounting in fuse-boxes or switchgearcabinets, mounting height 55 mm

Bild 1 Kaltleiter-Relais Typ MSR220K2

PTC-Resistor-Relay Type MSR220K2

ZIEHL PTC-resistor relays protect motors, transformers, machines and equipment against thermal overload. With ZIEHL PTC Sensors MINIKA ® applied they offer best solutions for nominal response temperatures 60°C…180°C.ZIEHL PTC-resistor relays are designed for PTC-sensors according to DIN 44081 and DIN 44082. Therefor sensor and relays are exchangeable. PTC-resistor sensors are suitable for the installation into windings of electrical machines, bearings and transformers as well as to monitor the temperature of liquid media, airflow and gases.Used in conjunction, they provide a effectively and reliable protection in case ofblocking rotors, heavy starts, countercurrent operationundervoltage and phase failureincreased ambient temperature and hindered coolingThe MSR220K2 monitors 2 PTC resistor sets at the same time. If a temperature rise occurs in one set, the appropriate output relay releases. With this relay, 2 PTC-sets can be independently monitored. Functional overview2 PTC-resistor sets, each 1...6 PTC resistors, or bimetal contactsoutput relays 2 x 1 change-over contact (co)LEDs for operation and alarmelectronic reclosing lock (disconnectable)integrated RESET-buttonlink for external RESETautomatic RESET at voltage recoveryUL-Recognized Component  ATTENTION:Replacement item for T221923 AC/DC 24V = T221943: Version with reset functionReplacement item for T221925 AC 230V = T221945: Version with reset function

Bild 1 Niveaurelais Typ NS20

Level Relay Type NS20

Level-Relays NS 20 for conductive liquids can be used as monitors for 1 Level and for controlling a level between 2 electrodes.3 elektrodes for MIN/MAXcontrol2 elektrodes (E2 open) as level monitorSensitivity adjustable 5 kO…250 kOLED for state of relayFunction of relay reversible (picks up or releases at top electrode)Switching-delay adjustable 0,1…10 sHousing 35 mm wide, mounting height 55 mmUniversal supply-voltage AC/DC 24-240 VApplication level monitorProtection from running dry or overflow, monitoring of pumps for leaks, detection of leaks.Application Min/MaxControlling a level between minimum (elektrode E2) and maximum (E3). As long as E3 is dry, a magnetic valve is opened (or a pump is running) and liquid is influenting. As soon as maximum (E3) is reached, the NS 20 closes the valve. When the level falls below E2, the cycle starts new. In reverse also discharging of a container can be controlled.Overview of functions example filling with 2 electrodesThe detection of the level is made with a DC-free measuring of resistance between all electrodes The common electrode in E 1. A magnetic valve that is switched with relay-contacts 15-18 opens and lets liquid in until the upper electrode E3 is in contact with the liquid. Then the relay releases (15-18 open) and the valve closes. The relay remains released as long as electrode E 2 is in contact with the liquid. When the level falls below E2, the relay picks up (LED Relay on, 15-18 close) and the procedure starts new with opening the valve. Thus thelevel of the liquid is kept between E 1 and E 2.For monitoring one level only or in applications to protect from running dry or overflow or leak detection, only electrodes E1 and E3 are connected.

Bild 3 Kaltleiter-Relais Typ MS220K

PTC-Resistor-Relay Type MS220K

Changes from T221745 AC220-240V, 1U to T228102 Changes from T221741, T221743, T221761, T221765 to T228111 with ResetVersions with spring terminals RoHS/REACH compliant. Further information can be found in our customer information: "New terminals for K-type devices"ZIEHL PTC-resistor relays protect motors, transformers, machines and equipment against thermal overload. With ZIEHL PTC Sensors MINIKA ® applied they offer best solutions for nominal response temperatures 60°C…180°C.ZIEHL PTC-resistor relays are designed for PTC-sensors according to DIN 44081 and DIN 44082. Therefor sensor and relays are exchangeable. PTC-resistor sensors are suitable for the installation into windings of electrical machines, bearings and transformers as well as to monitor the temperature of liquid media, airflow and gases.Used in conjunction, they provide a effectively and reliable protection in case ofblocking rotors, heavy starts, countercurrent operationundervoltage and phase failureincreased ambient temperature and hindered coolingFunctional overview1 PTC-resistor set with up to 6 PTC-sensors (250O), or bimetal contacts in seriesoutput relay with 1 or 2 change-over contact (co)operating status display with LEDK-Housing, vertical terminal orderwidth 22.7 mmsnap mounting on 35 mm standard DIN rail or screw mounting 

Bild 1 TR660IP, Temperaturrelais für Pt 100, PT1000, PTC 6 Sensoren, 7 Limits, TCP/IP

Temperature Relay Type TR660IP

Temperature Relays TR660IP monitor up to 6 sensors for up to 7 limits. Different sensors can be connected at the same time, e.g. Pt 100 (RTD) and PTC thermistors. Typical applications are monitoring of motors, generators or transformers. An other application is the use as a two or more step controller with additional monitoring of over- or undertemperature or monitoring of differences in temperatures of 2 sensors.Preset programs allow easy setting e.g. monitoring of transformers with/without monitoring of temperature of core or with/without controlling a ventilator.If the evaluation "2 out of x" is activated with several connected sensors, an alarm is only triggered when the limit value is exceeded in 2 sensors. This prevents false alarms due to a fault in one sensor. Operation can be made at the device or with a standard browser via Ethernet.6 inputs for sensors Pt 100, Pt 1000 and PTC, mixed sensors possible7 alarms / relay outputsalarm 2 of x = alarm only when limit is exceeded in min. 2 sensorsmonitoring of difference of temperaturesmonitoring of rate of change of temperaturelogging of temperatures and historypreset programs for protection of motors, transformers and moreinterface ethernet TCP/IP, values available via modbus TCPprogramming with browser via TCP/IP or with joystick at devicecoloured LED display for clear display of temperatures and states of alarmsuniversal power supply AC/DC 24-270 VAccessory: Installation frame ER8 for panel mount ZIEHL devices neatly integrated into control panels and control cabinet doors with our installation frames type ER! More information here TR660IP RS485:  interface RS485 (modbus RTU)TR660IP analog:  4 analog outputs 2x 0/4 - 20 mA and 2x 0/2 - 10 V, isolated from sensor inputs, individually programmable.  Discover the difference between our TR640IP, TR660IP and UR840IP! Type TR640IP TR660IP UR840IP Sensors PTC, Pt100, Pt1000 PTC, Pt100, Pt1000 Pt100, Pt1000, KTY83, KTY84, thermocouples, 0-10V, 0/4-20mA Sensor inputs 6 6 8 Digital inputs - - 4 Outputs 4x alarm relays 6x alarm relays, 2x analog (only T224370) 4x alarm relays, 1x analog Alarm types Limit value, differential, rate of change of temperature, 2 out of x Limit value, differential, rate of change of temperature, 2 out of x Sensor-specific limit values, differential, average, min/max, 2 out of x Virtual sensors - - 8 Display Display, LED Display, LED Display, LED Network / Communication Ethernet RS485 (only T224371), Ethernet RS485, Ethernet Other functions On/off delay, simulation, cyclic relay test, 2 digital inputs On/off delay, simulation, cyclic relay test, 2 digital inputs On/off delay, simulation, expansion with URB or STWA4MH Housing V6 V8 V8

Bild 1 Kaltleiter-Relais Typ MSR220K6

PTC-Resistor-Relay Type MSR220K6

The MSR220K6 monitors up to 6 PTC-resistors sets with up to 6 PTCs each at the same time. If a temperature rise occurs in one set, the output relay releases and LEDs show the overheated sensor. Switching-off is stored until a Reset. Thus enables to find the overheated sensor even when it has cooled down.Changes from T221958 to T228128: Version with spring terminals RoHS/REACH compliantFurther information can be found in our customer information: "New terminals for K-type devices"With the MSR220K6 only 4 mm space is needed per monitored PTC-circuit. It is especially suitable for monitoring drives with multiple motors, like cranes or robots. Instead of the PTC-sensors also contacts (normally closed) can be connected.6 PTC-resistor sets, each 1...6 PTCMonitoring of short-circuit of sensorOutput relay 1 x change-over contactElectronic reclosing lock (disconnectible with bridge)Input for external RESETAutomatic RESET at voltage recoveryLED for power on (green)6 LEDs for display of overheated sensorUniversal supply voltage AC/DC 24-240 V

Bild 1 Kaltleiter-Relais Typ MS220VA

PTC-Thermistor-Relay Type MS220VA

ZIEHL PTC thermistor relays protect motors, transformers, machines and equipment against thermal overload. Used in conjunction with respective PTC thermistors they provide a reliable temperature protection in the temperature range 60 °C up to 180 °C.The device is conform to EN IEC 60947-8. Thermistors according to DIN VDE V 0898-1-401 (ATEX) or equivalent detail specification (UKEX) shall be connected. PTC thermistors are suitable for the installation into windings of electrical machines, bearings and transformers as well as to monitor the temperature of liquid media, airflow and gases. With ATEX approval, explosion-protected equipment in explosive gas atmospheres (marking G: gas) or in areas with combustible dust (marking D: dust) can be protected.FeaturesATEX directive 2014/34/EU1 circuit for 1, 3 or 6 PTC thermistorsShort-circuit detection within the thermistor circuitOutput relay with 1 change-over contact (co)Operating status display with LED

Bild 1 Kaltleiter-Relais Typ MS40ZT

PTC-Resistor-Relay Type MS40ZT

The PTC-resistor relay MS 40 ZT monitors particularly engines at elevator cars and lifts. A pulse input monitors the movement of the elevator car as long as the motor is switched on.watchdog timing adjustable 5 - 50 s.temperature monitoring with PTC-resistorintegrated RESET-buttonLED for temperatur alarmLED for watchdog alarmAt elevator systems the temperature of the motor and the travelling motion have to be monitored. With the car at rest and contact between terminals 2 and 5 closed, the integrated relay picks up (terminals 8, 9 connected). The time monitoringstarts with the opening of the contact between terminals 2 and 5. Then the pulse input between terminals 3 and 6 must continously open and closeduring travelling motion. When the pulse stops or the nominal response temperature of the PTC-resistor is exceeded, the relay releases. Each disconnection is locked. A restart by pressing the RESET-button is only possiblewith closed contact between terminals 2 and 5 and low-resistive sensor.

Bild 1 Drehstromwächter Typ PSSW1

Monitor for 3-phase Type PSSW1

Relays for 3-phase networks type PSSW1 monitor 3-phase networks for phase-sequence, asymmetry and over- and undervoltage.ApplicationsMonitoring of 3-phase-networks at heat pumps, compressors or at machines at building sites.FunctionsOver- and undervoltage, adjustable ± 2-20 % (common)Asymmetry adjustable 5-15%Phase lossPhase sequenceSwitching delay adjustable 0,1-12 s (for voltage and asymmetry)Bifrequential measuring input 50/60 HzDisplays (4 LEDs for)Over-/undervoltageAsymmetryPhase-sequence/lossState of relay 

Bild 1 MSR820V, Kaltleiter-Relais, 8-kanalig, Reset, AC/DC 24-240 V, Verteilereinbaugehäuse 4 TE

PTC-Resistor-Relay Type MSR820V

The MSR820V monitors up to 8 PTC-resistor-circuits at the same time. A common relay signals an alarm or an error in a sensorcircuit. The inputs can be enabled or disabled during operation. The MSR820V can also be used as a fault annuciator for collective reports.1-8 PTC-circuits, each 1…6 PTC in series (max. coldresistance 1500O/circuit)Easy activating/deactivating of PTC-circuits (display with LEDs)2 potential-free relay-outputs, display of switching state with LEDsDisplay of state of PTC-circuits with 2 LEDs per circuitElectronic reclosing-lock (disconnectible with bridge Y1-Y2)monitoring of contacts for collective fault-reportsProgrammable functions:– Monitoring of short-circuit of PTCs (OFF / ON)– External Reset as normally closed (nc) or open (no) contact (Y1, Y2)– Power-fail-safe reclosing lock (OFF / ON)– Function of relay:    – K1 and K2 closed-current mode    – K1 and K2 operating-current mode    – K1 closed- and K2 operating-current-modeUniversal supply-voltage AC/DC 24 – 240 VMounting on DIN-rail 35mm EN 60715 or wallmount (Option)Mounting height 55 mmAccessory: Installation Frame ER4 for panel mount

How may I assist you?
ProxaChatbaseAI.questions.logo

Zetty

Digital Assistant

ProxaChatbaseAI.questions.logo

Welcome to ZIEHL industrie-elektronik GmbH + Co KG! I am Zetty, your digital assistant. Since many of my answers are generated by artificial intelligence, please double-check important information to make sure everything is correct.

Content partly AI-generated. Before using our products, it is necessary by qualified personnel is required. No liability for incorrect information. Learn more
ProxaChatbaseAI.questions.logo