Vibrator Control Type RS1K

The vibrator control RS1K is a compact multiple time relay for triggering of vibrators in suction plants. In order to be able to operate suction plants at an optimum, the filters which get clogged by sawdust, chips or dust, have to be dedusted by vibration from time to time. The vibration action is by no means to be carried out the suction running or while slowing down the ventilator. If suctioning is started during vibration, the process is immediately to be interrupted. Prior to starting the vibration action, an adjustable deceleration time is running to delay the ventilator before start of vibration. This means that short stoppages can be bypassed without being obliged to carry out a vibration every time.

Changes from Z224302 to Z227800: Version with spring terminals RoHS/REACH compliant
Further information can be found in our customer information: "New terminals for K-type devices"

  • Start of deceleration time by break contact at Y1/Z0 (e.g. from contactor suction motor)
  • Starting of deceleration time through current transformer STWA 1 at Z0/Z1 (e.g. L1 from suction motor)
  • adjustable deceleration time 1...30 min.
  • Relay K1: continous vibration 20 s or impulsevibration 18 s with 3 s clock
  • Relay K2: impulse-vibration 40 s with clock 0,5 s or 0,8 s (for magnet valves)
  • LED (red) signals deceleration time
  • LED (green) signals vibration action
  • automatic interruption of the vibration action when starting the suction process.

Discover the difference between RS1K and RS2K!

Type RS1K RS2K
Rapping time point Tn after switching on the first machine After S(machine runtime) = Tn
Tn 1 - 30 min 5 - 30 min
Run-down time - 60s
Rapping interval K1: for 18s in 3s or continuous vibrating for 20s K1: or 18s in 3s or continuous vibrating for 20s
K2: every 0,5s or 0,8s K2: every 0,5s or 1s
Display Device power on: - Device power on: LED green
Waiting for vibration time: LED red Waiting for vibration time: LED yellow
Cleaning active: LED green Cleaning active: LED green flashing
Run-down time: - Run-down time: LED yellow flashing
Control voltage AC/DC 24 - 240 V AC/DC 24 - 270 V
Applications: Controils for suction plants
Approval: EU / UKCA-Declaration of Conformity
Design: Mount in switchgear cabinet
Input/ Measured parameter: Current detection yes/no, Digital input
Outputs: Outputs/Relays
Product group: Switching Relays and Controls
Skip product gallery

Alternativ

Bild 1 Rüttlersteuerung Typ RS2K
Vibrator Control Type RS2K

The vibrator control RS2K is a compact multiple time relay for triggering of vibrators in suction plants. In order to be able to operate suction plants at an optimum, the filters which get clogged by sawdust, chips or dust, have to be dedusted by vibration from time to time. The vibration action is by no means to be carried out the suction running or while slowing down the ventilator. If suctioning is started during vibration, the process is immediately to be interrupted. Prior to starting the vibration action, an adjustable deceleration time is running to delay the ventilator before start of vibration. This means that short stoppages can be bypassed without being obliged to carry out a vibration every time.Start of deceleration time by break contact at Y1/Z0 (e.g. from contactor suction motor)Starting of deceleration time through current transformer STWA 1/STWA1H at Z0/Z1 (e.g. L1 from suction motor)adjustable deceleration time 5...30 min.Relay K1: continous vibration 20 s or impulsevibration 18 s with 3 s clockRelay K2: impulse-vibration 40 s with clock 0.5 s or 1.0 s (for magnet valves)LED (yellow) signals deceleration timeLED (green) signals vibration actionautomatic interruption of the vibration action when starting the suction process.Discover the difference between RS1K and RS2K! Type RS1K RS2K Rapping time point Tn after switching on the first machine After Σ(machine runtime) ≥ Tn Tn 1 - 30 min 5 - 30 min Run-down time - 60s Rapping interval K1: for 18s in 3s or continuous vibrating for 20s K1: or 18s in 3s or continuous vibrating for 20s K2: every 0,5s or 0,8s K2: every 0,5s or 1s Display Device power on: - Device power on: LED green Waiting for vibration time: LED red Waiting for vibration time: LED yellow Cleaning active: LED green Cleaning active: LED green flashing Run-down time: - Run-down time: LED yellow flashing Control voltage AC/DC 24 - 240 V AC/DC 24 - 270 V

Questions about Vibrator Control Type RS1K
ProxaChatbaseAI.questions.logo

Zetty

Digital Assistant

ProxaChatbaseAI.questions.logo

Welcome to ZIEHL industrie-elektronik GmbH + Co KG! I am Zetty, your digital assistant. Since many of my answers are generated by artificial intelligence, please double-check important information to make sure everything is correct.

Content partly AI-generated. Before using our products, it is necessary by qualified personnel is required. No liability for incorrect information. Learn more
ProxaChatbaseAI.questions.logo