Control for extraction systems vie bus type STW164IP

Control for extraction systems with connection slide valve via bus, control of up to 32 sliders via bus line

Share: Facebook   WhatsAppWhatsApp   E-Mail


Experience ZIEHL-Product live

User: Test
Password: Test

Product description

 

The basic function of the device is to detect whether a current is flowing in the supply line of one of several woodworking machines. If a current flow is detected, the device opens a valve on the machine's suction channel. At the same time, the extraction system is switched on. When a machine is switched off, the device closes the associated valve with a delay. If the last machine is switched off, the extraction system also stops after a delay.

Control for extraction systems with connection slide valve via bus, control of up to 32 sliders via bus line

Accessory: Installation frame ER8 for panel mount

Technical Data STW164IP

Rated supply

Rated suply voltage Us

.......

DC 24 V

 
 

Tolerance

.......

DC 20 - 30 V

 

Power consumption

.......

< 3 W

 

Relay outputs K1, K2, K3, K4

.......

4 x 1 Wechsler

 

switching elements

.......

max AC 300 V, DC 300 V

 

Inrush current normally open (no)

.......

AC 15 A, 4 s, 10% ED

 

Minimum voltage/current

.......

12 V, 10 mA

 

Conventional thermal current Ith

.......

max. 5 A

 

Switching capacity max AC cosfi = 1

.......

2000 VA

 

Inputs I0...I15

Connectable converters

.......

STWA1(H), potential-free contact, Stromsensor S1

 

Overload witch STWA1(H)

.......

max. 100 A continuous, max. 300 A für 10 s

 

Inputs Y1, Y2

internal resistance

.......

approx. 38 kOhm

 

switching threshol

.......

EIN > 17 V, AUS < 8 V

 

EMC test

.......

EN 61326-1

 

Emmision/RFI suppression

.......

CISPR 11 class B/ industrial environment

 

permissible ambient temperature

.......

-20°C…+55°C

 

Shaking safety EN 60068-2-6

.......

2...13,2 Hz +/- 1 mm  13,2...100 Hz 1 g
2...25 Hz +/- 1,6 mm  25...150 Hz 5 g

 

Housing

Design / Installation Frame

.......

V8 switchgear mount / Front mounting kit ER8, 8 TE

 

Dimensions (w x h x d) mm

.......

140 x 90 x 58 mm, mounting height 55 mm (8 TE)

 

Cable connection solid

.......

1 x 0,34-1,5 mm2 / AWG 22-14

 

Finely stranded with end sleeve

.......

1 x 0,1-1 mm2 / AWG 27-16

 

Stripping length/torgue

.......

8 mm/0,5 Nm

 

Attachement

.......

Snap-on mounting rail 35 mm according to EN 60 715 or screw fixing M4 (additional bolts not included)

 

Protection housing/terminals

.......

IP 30/ IP 20

 

Weight

.......

approx. 310 g