Skip to main content Skip to search Skip to main navigation
Go to homepage

Pt100-Temperature-Sensors Type TF101R

TF101 temperature sensors use EN 60751/IEC 60751 platinum resistance temperature detectors (RTD). For precise temperature measurement the Platinum Resistance Thermometer offers the best overall advantages in repeatability and stability over a long period. High accuracy allows replacement of a sensor without any need for re-adjust of the connected measuring devices or thermostats. TF101 temperature sensors are available in different designs.

Sensor for measuring ambient temperatures inside or outside. Protection class IP 54. Cabling can be connected in 2- or 3- wire technique.

Product group: Temperature Measurement
Input/ Measured parameter: Pt 100
Extras: Temperature sensors
Skip product gallery

Alternative

Bild 1 Pt100-Temperatursensoren Typ TF101G3
Pt100-Temperature-Sensors Type TF101G3

TF101 temperature sensors use EN 60751/IEC 60751 platinum resistance temperature detectors (RTD). For precise temperature measurement the Platinum Resistance Thermometer offers the best overall advantages in repeatability and stability over a long period. High accuracy allows replacement of a sensor without any need for re-adjust of the connected measuring devices or thermostats. TF101 temperature sensors are available in different designs.Platinum resistance temperature sensor on ceramic substrate built into a M6 brass threaded bush, especially suitable for being screwed into metal, e.g. for monitoring temperature of heat sinks or heating plates. Please note that there will be a measuring error due to the design, as the sensor can loose heat via the connection strand. Cable length: 2000 mmWeight: 21 g.(Dimensions see Dimension illustrations)

Bild 1 TF101K, Sensor Pt 100 Bauform K
Pt100-Temperature-Sensors Type TF101K

TF101 temperature sensors use EN 60751/IEC 60751 platinum resistance temperature detectors (RTD). For precise temperature measurement the Platinum Resistance Thermometer offers the best overall advantages in repeatability and stability over a long period. High accuracy allows replacement of a sensor without any need for re-adjust of the connected measuring devices or thermostats. TF101 temperature sensors are available in different designs.The TF1001/K design is suitable for installation in transformer and motor windings. When installing in windings, ensure that the measuring resistor is not subjected to pressure and that there is no tensile load on the cable.Cable length: 2000 mmWeight: approx. 10 g

Bild 1 Pt100-Temperatursensoren Typ TF101N
Pt100-Temperature-Sensors Type TF101N

TF101 temperature sensors use EN 60751/IEC 60751 platinum resistance temperature detectors (RTD). For precise temperature measurement the Platinum Resistance Thermometer offers the best overall advantages in repeatability and stability over a long period. High accuracy allows replacement of a sensor without any need for re-adjust of the connected measuring devices or thermostats. TF101 temperature sensors are available in different designs.Platinum resistance temperature sensor on ceramic substrate intended for installation into any housing depending to user’s requirements. Very small and quick sensor, only suitable for further treatment. Notice: do not cut the sensor leads. Thermal response time refer to manufacturer data: T0,9 in the air 10 s, in water <1 s.

Bild 1 TF101U2, Sensor Pt 100 Bauform U2
Pt100-Temperature-Sensors Type TF101U2

TF101 temperature sensors use EN 60751/IEC 60751 platinum resistance temperature detectors (RTD). For precise temperature measurement the Platinum Resistance Thermometer offers the best overall advantages in repeatability and stability over a long period. High accuracy allows replacement of a sensor without any need for re-adjust of the connected measuring devices or thermostats. TF101 temperature sensors are available in different designs.Platinum resistance temperature sensor on ceramic substrate intended for installation into any housing depending to user’s requirements. Very small and quick sensor, only suitable for further treatment. Notice: do not cut the sensor leads. Thermal response time refer to manufacturer data: T0,9 in the air 10 s, in water <1 s.Weight:PVC: 2m = 50g, 10m = 250, 30 mm = 15gPTFE: 2m = 20g

Bild 1 TF101ZG2, Sensor Pt 100, -50...+ 170 °C, Edelstahlrohr V4A, Gewinde 1/2 Zoll, 110 mm
Pt100-Temperature-Sensors Type TF101ZG2

Temperature sensors of the TF101 series are resistance thermometers (RTD sensors) and contain a platinum measuring resistor in accordance with EN 60751 / IEC 60751. It has a high long-term stability and the measurement is accurate over a long period of time with temperature sensors of this type series. The close tolerance of the measuring resistors makes it possible to replace the sensors without having to recalibrate the connected measuring or switching devices while retaining the measuring cable length.Platinum resistance temperature sensor built into steel tube V4A, 1/2 inch, suitable for installation in pipes. Thermal response time T0,9 in the air 255 s, in water 45 s. Connection flat plug 2,8 mm, Gasket IP55, clamping diameter 8-12 mm, cable connecthead max. 100 °CSuitable for transmission in 2- or 3-wire technique.Weight 120 g(Dimensions see Dimension illustrations)

Questions about Pt100-Temperature-Sensors Type TF101R
ProxaChatbaseAI.questions.logo

Zetty

Digital Assistant

ProxaChatbaseAI.questions.logo

Welcome to ZIEHL industrie-elektronik GmbH + Co KG! I am Zetty, your digital assistant. Since many of my answers are generated by artificial intelligence, please double-check important information to make sure everything is correct.

Content partly AI-generated. Before using our products, it is necessary by qualified personnel is required. No liability for incorrect information. Learn more
ProxaChatbaseAI.questions.logo