Transformer Protection Temperature Relay Type TR440

Version

Price after log in

Temperature relay to protect transformers against excess temperature and to control a fan.
The temperatures in the windings are monitored with three Pt 100 sensors. The core temperature can be monitored with a fourth sensor.
The 4 alarms/output relays are used to control the fan, to signal an advance warning and to switch-off the transformer. Various programs facilitate using the alarm ideally for each application. Depending on the program, e.g. an extra relay is available for the fault message or for triggering due to exceeding the maximum core temperature.

Other uses

Alternatively, with the fourth sensor the temperature of the room the transformer is located in can be monitored and, with the alarm, the room ventilation can be controlled. The device can also be used for other tasks for temperature monitoring
e.g., for motors.

Overview of the functions

  • 4 Sensor inputs Pt 100 (RTD), 2 or 3-wire connection
  • Large monitoring range -199…+850°C / -199...+999°F
  • 4 Alarms / Relays
  • 3-digit digital display (resolution 1°C / 1°F)
  • 4 LEDs sensor
  • 4 LEDs relay
  • 4 LEDs alarm
  • 1 LED error
  • Control voltage AC/DC 24-240 V
  • Clear displays and simple programming
  • Min and max sensor values can be saved
  • Code lock against unintended / unauthorised changes to the settings
  • Optional RS 485 interface with Modbus RTU protocol
  • EasySimulation for simple sensor value simulation
 

Alternative

Tip
Temperature Relay Type TR640IP
Temperature Relays TR640IP monitor up to 6 sensors for up to 4 limits. Different sensors can be connected at the same time, e.g. Pt 100 (RTD) and PTC thermistors. Typical applications are monitoring of motors, generators or transformers. An other application is the use as a two or more step controller with additional monitoring of over- or undertemperature or monitoring of differences in temperatures of 2 sensors.Preset programs allow easy setting e.g. monitoring of transformers with/without monitoring of temperature of core or with/without controlling a ventilator.If evaluation "2 out of x" is activated with several connected sensors, an alarm is only triggered when the limit value is exceeded in 2 sensors. This prevents false alarms due to a fault in one sensor. Operation can be made at the device or with a standard browser via Ethernet.6 inputs for sensors Pt 100, Pt 1000 and PTC, mixed sensors possible4 alarms / relay outputsalarm 2 of x = alarm only when limit is exceeded in min. 2 sensorsmonitoring of difference of temperaturesmonitoring of rate of change of temperaturelogging of temperatures and historypreset programs for protection of motors, transformers and moreinterface ethernet TCP/IP, values available via modbus TCPprogramming with browser via TCP/IP or with joystick at devicecoloured LED display for clear display of temperatures and states of alarmsuniversal power supply AC/DC 24-270 VAccessory: Installation frame ER6 for panel mount